ArticleJOR spine2019
Slow depressurization following intradiscal injection leads to injectate leakage in a large animal model.
Article in JOR spine, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 10 papers, 1 of them a synthesis that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
10 citing papers in PubMed, 1 synthesis or guideline pooled it, 14 citations in OpenAlex.
- Extracellular Vesicles as an Emerging Treatment Option for Intervertebral Disc Degeneration: Therapeutic Potential, Translational Pathways, and Regulatory Considerations.Advanced healthcare materials · 2022Pooled it
- TGF-β/SMAD signaling maintains nucleus pulposus stem cell quiescence to protect against oxidative injury in intervertebral disc degeneration.Stem cell research & therapy · 2026Article
- Papain Injection Creates a Nucleotomy-like Cavity for Testing Gels in Intervertebral Discs.Gels (Basel, Switzerland) · 2024Article
- Single-Cell Microgel Encapsulation Improves the Therapeutic Efficacy of Mesenchymal Stem Cells in Treating Intervertebral Disc Degeneration via Inhibiting Pyroptosis.Research (Washington, D.C.) · 2024Article
- Intervertebral disc degeneration-Current therapeutic options and challenges.Frontiers in public health · 2023Review
- Establishing a through-puncture model for assessing post-injection leakage in the intervertebral disc.European spine journal : official publication of the European Spine Society, the European Spinal Deformity Society, and the European Section of the Cervical Spine Research Society · 2022Article
- Gene Therapy in Orthopaedics: Progress and Challenges in Pre-Clinical Development and Translation.Frontiers in bioengineering and biotechnology · 2022Review
- Proteoglycan-depleted regions of annular injury promote nerve ingrowth in a rabbit disc degeneration model.Open medicine (Warsaw, Poland) · 2021Article
- Slow depressurization following intradiscal injection leads to injectate leakage in a large animal model.JOR spine · 2019Article
- Hydrogel-Embedded Poly(Lactic-CartilageArticle
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
3 authors at 1 institution in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Needle injection has been indicated as the most practical method of delivering therapeutic agents to the intervertebral disc due to the disc's largely avascular nature. As the disc is characterized by both high stiffness and low permeability, injection requires substantial pressure, which may not relax on practical time scales. Additionally, needle puncture results in a localized disruption to the annulus fibrosus that can provide a leakage pathway for pressurized injectate. We hypothesized that intradiscal injection would result in slow relaxation of injectate pressure, followed by leakage upon needle retraction. This hypothesis was tested via controlled injection of fluorescently labeled saline into bovine caudal discs via a 21 gauge needle. Injections were performed with 10% of total disc volume injected at 3%/s followed by a 4-minute dwell. An analytical poroelastic model was calibrated to the experimental data and used to estimate injectate delivery with time. Experimental results confirmed both pressurization (with a peak of 199 ± 45 kPa) and slow recovery (final pressure of 81 ± 23 kPa). Injectate leakage through the needle puncture was verified following needle retraction in all samples. Histological sections of the discs displayed a clear defect at each disc's injection site with strong fluorescent labeling indicating a leakage pathway. The modeling results suggest that less than one-fourth of the injected volume was absorbed by the tissue in 4 minutes. Taken together these results suggest that needle injection is a feasible, albeit inefficient method for delivery of therapeutic agents into the intervertebral disc. Particular care should be taken to aspirate un-absorbed injectate prior to needle retraction to prevent leakage and exposure of surrounding tissues.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.