Evidence map›Paper›PMID 31568960›Full record

ArticleApplied ergonomics2020

Influence of averaging time-interval on shoe-floor-contaminant available coefficient of friction measurements.

Kurt E Beschorner, Arian Iraqi, Mark S Redfern, Brian E Moyer, Rakié Cham

Abstract read
In one paragraph

Article in Applied ergonomics, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Kurt E BeschornerDepartment of Bioengineering, University of Pittsburgh, Benedum Engineering Hall #302, 3700 O'Hara St., Pittsburgh, PA, 15261, United States. Electronic address: beschorn@pitt.edu.
Arian IraqiDepartment of Bioengineering, University of Pittsburgh, Benedum Engineering Hall #302, 3700 O'Hara St., Pittsburgh, PA, 15261, United States. Electronic address: ari16@pitt.edu.
Mark S RedfernDepartment of Bioengineering, University of Pittsburgh, Benedum Engineering Hall #302, 3700 O'Hara St., Pittsburgh, PA, 15261, United States. Electronic address: mredfern@pitt.edu.
Brian E MoyerCrossroads Consulting, LLC, 1334 Luzerne St Ext, Johnstown, PA, 15905, United States; Mechanical Engineering, University of Pittsburgh Johnstown, Johnstown, PA, 15905, United States. Electronic address: moyer@xroads-consulting.com.
Rakié ChamDepartment of Bioengineering, University of Pittsburgh, Benedum Engineering Hall #302, 3700 O'Hara St., Pittsburgh, PA, 15261, United States; Department of Physical Therapy, University of Pittsburgh, United States; Department of Ophthalmology, University of Pittsburgh, United States. Electronic address: rcham@pitt.edu.

Funding

VARIABILITY, STABILITY & SMOOTHNESS OF WALKINGP30AG024827 · NIA · UNIVERSITY OF PITTSBURGH AT PITTSBURGH · PI Caterina Rosano · 2004 to 2026
$28.6M
Preventing Slips in Food Service: Development of Tools for Shoe Selection and ReplacementR01OH010940 · OH · UNIVERSITY OF PITTSBURGH AT PITTSBURGH · PI BESCHORNER, KURT E, SOMMERICH, CAROLYN M · 2015 to 2025
$3.1M
Portable Slip-Testing Device for Measuring Shoe-Floor Coefficient of FrictionR44AG059258 · NIA · CROSSROADS CONSULTING, LLC · PI BESCHORNER, KURT E, MOYER, BRIAN EVAN · 2017 to 2018
$1.3M
Biomechanics of Slips in Older AdultsR01OH007592 · OH · UNIVERSITY OF PITTSBURGH AT PITTSBURGH · PI CHAM, RAKIE · 2002 to 2009
$940k
Modeling Shoe-Floor Interface Properties to Predict Slips and FallsR01OH008986 · OH · UNIVERSITY OF PITTSBURGH AT PITTSBURGH · PI REDFERN, MARK S · 2010 to 2012
$899k
Motion Capture SystemS10RR027102 · NCRR · UNIVERSITY OF PITTSBURGH AT PITTSBURGH · PI CHAM, RAKIE · 2011 to 2011
$232k
Biofidelic Slip-Testing Device for Measuring & Analyzing Shoe-Floor FrictionR43AR064111 · NIAMS · CROSSROADS CONSULTING, LLC · PI MOYER, BRIAN · 2013 to 2013
$150k
NCRR NIH HHS S10 RR027102NIAMS NIH HHS R43 AR064111NIA NIH HHS P30 AG024827NIA NIH HHS R44 AG059258NIOSH CDC HHS R01 OH007592NIOSH CDC HHS R01 OH008986NIOSH CDC HHS R01 OH010940
6 · The paper itself

Abstract

Available coefficient of friction (ACOF) is a common metric of footwear traction performance. ACOF is the ratio of friction to normal force, often averaged over a time-interval. The time-interval needed to achieve repeatable and valid ACOF is unknown. A post-hoc analysis was performed on nine shoe-floor-contaminant combinations to assess the repeatability and bias of data averaged across 4 time-intervals (2 ms, 50 ms, 100 ms, 200 ms) after the target normal force was reached. The ability to predict human slips was assessed for ACOF across these intervals. Differences in repeatability and validity across the four intervals were small. However, statistically significant differences were observed for the shortest compared with the longest interval (lower repeatability yet modestly improved predictive ability). Given the limited impact of time-interval on the results, a shorter interval of 50 ms is recommended to enable testing of smaller floor samples.

Indexed as

Floors and FloorcoveringsShoesAccidental FallsBiomechanical PhenomenaFrictionHumansReproducibility of ResultsSurface PropertiesTime FactorsShoe tractionSlips, trips, and fallsTribometers

Identifiers

PMID31568960
PMCPMC6922306

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.