ArticleIEEE transactions on ultrasonics, ferroelectrics, and frequency control2020

Estimation of Backscatter Coefficients Using an In Situ Calibration Source.

Trong N Nguyen, Alex J Tam, Minh N Do, Michael L Oelze

Abstract read
In one paragraph

Article in IEEE transactions on ultrasonics, ferroelectrics, and frequency control, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed.

  1. Toward Real-Time Backscatter Coefficient Estimation Incorporating the U-Net Segmentation and an In Vivo Reference Target.Journal of ultrasound in medicine : official journal of the American Institute of Ultrasound in Medicine · 2025
    Article
  2. Article
  3. Article
  4. Quantitative Ultrasound: Experimental Implementation.Advances in experimental medicine and biology · 2023
    Article
  5. Article
  6. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Trong N Nguyen
Alex J Tam
Minh N Do
Michael L Oelze

Funding

Detection and Grading of Fatty and Fibrotic Liver Using Quantitative UltrasoundR21EB020766 · NIBIB · UNIVERSITY OF ILLINOIS AT URBANA-CHAMPAIGN · PI OELZE, MICHAEL L. · 2015 to 2016
$420k
NIBIB NIH HHS R21 EB020766NIH HHS R21 EB020759
6 · The paper itself

Abstract

The objective of this article is to demonstrate the feasibility of estimating the backscatter coefficient (BSC) using an in situ calibration source. Traditional methods of estimating the BSC in vivo using a reference phantom technique do not account for transmission losses due to intervening layers between the ultrasonic source and the tissue region to be interrogated, leading to increases in bias and variance of BSC-based estimates. To account for transmission losses, an in situ calibration approach is proposed. The in situ calibration technique employs a titanium sphere that is well-characterized ultrasonically, biocompatible, and embedded inside the sample. A set of experiments was conducted to evaluate the embedded titanium spheres as in situ calibration targets for BSC estimation. The first experiment quantified the backscattered signal strength from titanium spheres of three sizes: 0.5, 1, and 2 mm in diameter. The second set of experiments assessed the repeatability of BSC estimates from the titanium spheres and compared these BSCs to theory. The third set of experiments quantified the ability of the titanium bead to provide an in situ reference spectrum in the presence of a lossy layer on top of the sample. The final set of experiments quantified the ability of the bead to provide a calibration spectrum over multiple depths in the sample. All experiments were conducted using an L9-4/38 linear array connected to a SonixOne system. The strongest signal was observed from the 2-mm titanium bead with the signal-to-noise ratio (SNR) of 11.6 dB with respect to the background speckle. Using an analysis bandwidth of 2.5-5.5 MHz, the mean differences between the experimentally derived BSCs and BSCs derived from the Faran theory were 0.54 and 0.76 dB using the array and a single-element transducer, respectively. The BSCs estimated using the in situ calibration approach without the layer and with the layer and using the reference phantom approach with the layer were compared to the reference phantom approach without the layer present. The mean differences in BSCs were 0.15, 0.73, and -9.69 dB, respectively. The mean differences of the BSCs calculated from data blocks located at depths that were either 30 pulse lengths above or below the actual bead depth compared to the BSC calculated at bead depth were -1.55 and -1.48 dB, respectively. The results indicate that an in situ calibration target can account for overlaying tissue losses, thereby improving the robustness of BSC-based estimates.

Indexed as

TransducersUltrasonographyCalibrationImage Processing, Computer-AssistedPhantoms, ImagingScattering, Radiation

Identifiers

PMID31567079
PMCPMC7075368

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.