ArticleMagnetic resonance in medicine2020

Non-Cartesian slice-GRAPPA and slice-SPIRiT reconstruction methods for multiband spiral cardiac MRI.

Changyu Sun, Yang Yang, Xiaoying Cai, Michael Salerno, Craig H Meyer, Daniel Weller, Frederick H Epstein

Abstract read
In one paragraph

Article in Magnetic resonance in medicine, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed.

  1. Article
  2. Article
  3. Spiral 2D T2-Weighted TSE Brain MR Imaging: Initial Clinical Experience.AJNR. American journal of neuroradiology · 2021
    Article
  4. Article
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Changyu SunDepartment of Biomedical Engineering, University of Virginia, Charlottesville, Virginia.ORCID 0000-0001-8102-7130
Yang YangDepartment of Medicine, University of Virginia Health System, Charlottesville, Virginia.
Xiaoying CaiDepartment of Biomedical Engineering, University of Virginia, Charlottesville, Virginia.
Michael SalernoDepartment of Biomedical Engineering, University of Virginia, Charlottesville, Virginia.
Craig H MeyerDepartment of Biomedical Engineering, University of Virginia, Charlottesville, Virginia.
Daniel WellerDepartment of Biomedical Engineering, University of Virginia, Charlottesville, Virginia.ORCID 0000-0001-9818-7325
Frederick H EpsteinDepartment of Biomedical Engineering, University of Virginia, Charlottesville, Virginia.

Funding

MRI of Myocardial Function in Post-Infarct Knockout MiceR01EB001763 · NIBIB · UNIVERSITY OF VIRGINIA CHARLOTTESVILLE · PI EPSTEIN, FREDERICK H · 2003 to 2020
$5.4M
High-Resolution Whole Heart Quantitative CMR Perfusion Imaging in Ischemic Heart DiseaseR01HL131919 · NHLBI · UNIVERSITY OF VIRGINIA · PI ENNIS, DANIEL B · 2017 to 2021
$3.5M
Free-breathing and simultaneous multislice cine DENSE myocardial strain imagingR01HL147104 · NHLBI · UNIVERSITY OF VIRGINIA · PI EPSTEIN, FREDERICK H · 2019 to 2022
$1.5M
NHLBI NIH HHS R01 HL131919NHLBI NIH HHS R01 HL147104NIBIB NIH HHS R01 EB001763
6 · The paper itself

Abstract

purposeSpiral MRI has advantages for cardiac imaging, and multiband (MB) spiral MRI of the heart shows promise. However, current reconstruction methods for MB spiral imaging have limitations. We sought to develop improved reconstruction methods for MB spiral cardiac MRI.

methodsTwo reconstruction methods were developed. The first is non-Cartesian slice-GRAPPA (NCSG), which uses phase demodulation and gridding operations before application of a Cartesian slice-separating kernel. The second method, slice-SPIRiT, formulates the reconstruction as a minimization problem that enforces in-plane coil consistency and consistency with the acquired MB data, and uses through-plane coil sensitivity information in the iterative solution. These methods were compared with conjugate-gradient SENSE in phantoms and volunteers. Temporal alternation of CAIPIRINHA (controlled aliasing in parallel imaging results in higher acceleration) phase and the use of a temporal filter were also investigated.

resultsPhantom experiments with 3 simultaneous slices (MB = 3) showed that mean artifact power was highest for conjugate-gradient SENSE, lower for NCSG, and lowest for slice-SPIRiT. For volunteer cine imaging (MB = 3, N = 5), the artifact power was 0.182 ± 0.037, 0.148 ± 0.036, and 0.139 ± 0.034 for conjugate-gradient SENSE, NCSG, and slice-SPIRiT, respectively (P < .05, analysis of variance). Temporal alternation of CAIPIRINHA reduced artifacts for both NCSG and slice-SPIRiT.

conclusionThe NCSG and slice-SPIRiT methods provide more accurate reconstructions for MB spiral cine imaging compared with conjugate-gradient SENSE. These methods hold promise for non-Cartesian MB imaging.

Indexed as

AlgorithmsImage EnhancementArtifactsHumansImage Processing, Computer-AssistedMagnetic Resonance ImagingPhantoms, ImagingGRAPPAmultibandsimultaneous multislicespiralSPIRiT

Identifiers

PMID31565819
PMCPMC7797187

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked