Evidence map›Paper›PMID 31564764›Full record

ArticleProceedings of SPIE--the International Society for Optical Engineering2017

A Patch-based CBCT Scatter Artifact Correction Using Prior CT.

Xiaofeng Yang, Tian Liu, Xue Dong, Xiangyang Tang, Eric Elder, Walter J Curran, Anees Dhabaan

Abstract read
In one paragraph

Article in Proceedings of SPIE--the International Society for Optical Engineering, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
1.5field-weighted citation impact, top 19% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed, 9 citations in OpenAlex.

  1. Article
  2. Article
  3. A Denoising Algorithm for CT Image Using Low-rank Sparse Coding.Proceedings of SPIE--the International Society for Optical Engineering · 2018
    Article
  4. High-resolution CT Image Retrieval Using Sparse Convolutional Neural Network.Proceedings of SPIE--the International Society for Optical Engineering · 2018
    Article
  5. Improving Image Quality of Cone-Beam CT Using Alternating Regression Forest.Proceedings of SPIE--the International Society for Optical Engineering · 2018
    Article
  6. Dosimetric study on learning-based cone-beam CT correction in adaptive radiation therapy.Medical dosimetry : official journal of the American Association of Medical Dosimetrists
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 1 institution in 1 country.

Xiaofeng YangDepartment of Radiation Oncology and Winship Cancer Institute, Emory University, Atlanta, GA.
Tian LiuDepartment of Radiation Oncology and Winship Cancer Institute, Emory University, Atlanta, GA.
Xue DongDepartment of Radiation Oncology and Winship Cancer Institute, Emory University, Atlanta, GA.
Xiangyang TangDepartment of Radiology and Imaging Sciences and Winship Cancer Institute, Emory University, Atlanta, GA.
Eric ElderDepartment of Radiation Oncology and Winship Cancer Institute, Emory University, Atlanta, GA.
Walter J CurranDepartment of Radiation Oncology and Winship Cancer Institute, Emory University, Atlanta, GA.
Anees DhabaanDepartment of Radiation Oncology and Winship Cancer Institute, Emory University, Atlanta, GA.
Emory University · US

Funding

Multiparametric MRI-guided Prostate HDR Brachytherapy with Focal Tumor BoostR01CA215718 · NCI · EMORY UNIVERSITY · PI YANG, XIAOFENG · 2018 to 2022
$1.8M
NCI NIH HHS R01 CA215718
6 · The paper itself

Abstract

We have developed a novel patch-based cone beam CT (CBCT) artifact correction method based on prior CT images. First, we used the image registration to align the planning CT with the CBCT to reduce the geometry difference between the two images. Then, we brought the planning CT-based prior information into the Bayesian deconvolution framework to perform the CBCT scatter artifact correction based on patch-wise nonlocal mean strategy. We evaluated the proposed correction method using a Catphan phantom with multiple inserts based on contrast-to-noise ratios (CNR) and signal-to-noise ratios (SNR), and the image spatial non-uniformity (ISN). All values of CNR SNR and ISN in the corrected CBCT image were much closer to those in the planning CT images. The results demonstrated that the proposed CT-guided correction method could significantly reduce scatter artifacts and improve the image quality. This method has great potential to correct CBCT images allowing its use in adaptive radiotherapy.

Indexed as

CBCTCTdeconvolutionscatter artifact correction

Identifiers

PMID31564764
PMCPMC6764528
OpenAlexW2591594885

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.