ArticleLab on a chip2019
High-throughput microfluidic micropipette aspiration device to probe time-scale dependent nuclear mechanics in intact cells.
Article in Lab on a chip, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 47 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
47 citing papers in PubMed, 89 citations in OpenAlex.
- Nuclear mechanotransduction: tools for mechanical perturbation and chromatin characterization.Nucleus (Austin, Tex.) · 2026Review
- Nuclear mechanobiology rules immune cells' functions: from differentiation to cell trafficking and pathogen killing.Nucleus (Austin, Tex.) · 2026Review
- Multiscale Architecture and Mechanics of the Cell Nucleus: Implications for Disease, Bioengineering and Nanomedicine.Advanced science (Weinheim, Baden-Wurttemberg, Germany) · 2026Review
- Viscoelasticity of the Heart: An Overview of Viscoelastic Measurements at Different Scales.Annual review of biomedical engineering · 2026Review
- Mechanical regulation of LINC complex function: structural basis, physiological roles, and disease mechanisms in transnuclear mechanotransduction.Frontiers in cell and developmental biology · 2026Review
- Polarization increases nuclear stiffness in macrophages despite reduction in lamin A/C levels.npj biological physics and mechanics · 2026Article
- Mechanical Signaling: Molecular Mechanisms, Biological Functions, Diseases, and Therapeutic Targets.MedComm · 2025Review
- At the Pointy End of Mechanobiology: AFM for Transient Biomechanical Analysis.Advanced healthcare materials · 2025Review
- Unlocking the therapeutic potential of cellular mechanobiology.Science advances · 2025Review
- Viscoelastic recovery times of chondrocytes measured using a novel 3D-printed microfluidic device.Measurement science & technology · 2025Article
- Dysfunctional mechanotransduction regulates the progression of PIK3CA-driven vascular malformations.APL bioengineering · 2025Article
- Metastatic organotropism in small cell lung cancer.bioRxiv : the preprint server for biology · 2025Article
- Dysfunctional mechanotransduction regulates the progression of PIK3CA-driven vascular malformations.bioRxiv : the preprint server for biology · 2024Article
- High throughput cell mechanotyping of cell response to cytoskeletal modulations using a microfluidic cell deformation system.Microfluidics and nanofluidics · 2024Article
- P300 Modulates Endothelial Mechanotransduction of Fluid Shear Stress.Cellular and molecular bioengineering · 2024Article
- Cell spheroid viscoelasticity is deformation-dependent.Scientific reports · 2024Article
- A high-throughput microfabricated platform for rapid quantification of metastatic potential.Science advances · 2024Article
- N-terminal tags impair the ability of lamin A to provide structural support to the nucleus.Journal of cell science · 2024Article
- Deformation under flow and morphological recovery of cancer cells.Lab on a chip · 2024Article
- Characteristics of nuclear architectural abnormalities of myotubes differentiated from LmnaIn vitro cellular & developmental biology. Animal · 2024Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
8 authors at 3 institutions in 2 countries.
Funding
Abstract
The mechanical properties of the cell nucleus are increasingly recognized as critical in many biological processes. The deformability of the nucleus determines the ability of immune and cancer cells to migrate through tissues and across endothelial cell layers, and changes to the mechanical properties of the nucleus can serve as novel biomarkers in processes such as cancer progression and stem cell differentiation. However, current techniques to measure the viscoelastic nuclear mechanical properties are often time consuming, limited to probing one cell at a time, or require expensive, highly specialized equipment. Furthermore, many current assays do not measure time-dependent properties, which are characteristic of viscoelastic materials. Here, we present an easy-to-use microfluidic device that applies the well-established approach of micropipette aspiration, adapted to measure many cells in parallel. The device design allows rapid loading and purging of cells for measurements, and minimizes clogging by large particles or clusters of cells. Combined with a semi-automated image analysis pipeline, the microfluidic device approach enables significantly increased experimental throughput. We validated the experimental platform by comparing computational models of the fluid mechanics in the device with experimental measurements of fluid flow. In addition, we conducted experiments on cells lacking the nuclear envelope protein lamin A/C and wild-type controls, which have well-characterized nuclear mechanical properties. Fitting time-dependent nuclear deformation data to power law and different viscoelastic models revealed that loss of lamin A/C significantly altered the elastic and viscous properties of the nucleus, resulting in substantially increased nuclear deformability. Lastly, to demonstrate the versatility of the devices, we characterized the viscoelastic nuclear mechanical properties in a variety of cell lines and experimental model systems, including human skin fibroblasts from an individual with a mutation in the lamin gene associated with dilated cardiomyopathy, healthy control fibroblasts, induced pluripotent stem cells (iPSCs), and human tumor cells. Taken together, these experiments demonstrate the ability of the microfluidic device and automated image analysis platform to provide robust, high throughput measurements of nuclear mechanical properties, including time-dependent elastic and viscous behavior, in a broad range of applications.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.