Evidence map›Paper›PMID 31559165›Full record

ArticleQuantitative imaging in medicine and surgery2019

Personalized 3D printed coronary models in coronary stenting.

Zhonghua Sun, Shirley Jansen

Open access · diamondAbstract read
In one paragraph

Article in Quantitative imaging in medicine and surgery, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 15 papers.

0numbers the graph read from it
0cells of the map it votes in
15citing papers in PubMed
2.4field-weighted citation impact, top 12% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

15 citing papers in PubMed, 44 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Review
  5. Review
  6. Article
  7. Review
  8. Article
  9. Review
  10. Article
  11. Article
  12. Review
  13. Article
  14. Article
  15. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

2 authors at 1 institution in 1 country.

Zhonghua SunDiscipline of Medical Radiation Sciences, School of Molecular and Life Sciences, Curtin University, Perth, Western Australia, 6845, Australia.
Shirley JansenDepartment of Vascular and Endovascular Surgery, Sir Charles Gairdner Hospital, Perth, Western Australia 6009, Australia.
Curtin University · AU

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

background3D printing has shown great promise in cardiovascular disease, with reports mainly focusing on pre-surgical planning and medical education. Research on utilization of 3D printed models in simulating coronary stenting has not been reported. In this study, we presented our experience of placing coronary stents into personalized 3D printed coronary models with the aim of determining stent lumen visibility with images reconstructed with different postprocessing views and algorithms.

methodsA total of six coronary stents with diameter ranging from 2.5 to 4.0 mm were placed into 3 patient-specific 3D printed coronary models for simulation of coronary stenting. The 3D printed models were placed in a plastic container and scanned on a 192-slice third generation dual-source CT scanner with images reconstructed with soft (Bv36) and sharp (Bv59) kernel algorithms. Thick and thin slab maximum-intensity projection (MIP) images were also generated from the original CT data for comparison of stent lumen visibility. Stent lumen diameter was measured on 2D axial and MIP images, while stent diameter was measured on 3D volume rendering images. 3D virtual intravascular endoscopy (VIE) images were generated to provide intraluminal views of the coronary wall and stent appearances.

resultsAll of these stents were successfully placed into the right and left coronary arteries but 2 of them did not obtain wall apposition along the complete length. The stent lumen visibility ranged from 54 to 97%, depending on the stent location in the coronary arteries. The mean stent lumen diameters measured on 2D axial, thin and thick slab MIP images were found to be significantly smaller than the actual size (P<0.01). Thick slab MIP images resulted in measured stent lumen diameters smaller than those from thin slab MIP images, with significant differences noticed in most of the measurements (4 out of 6 stents) (P<0.05), and no significant differences in the remaining 2 stents (P=0.19-0.38). In contrast, 3D volume rendering images allowed for more accurate measurements with measured stent diameters close to the actual dimensions in most of these coronary stents, except for the stent placed at the right coronary artery in one of the models due to insufficient expansion of the stent. Images reconstructed with sharp kernel Bv59 significantly improved stent lumen visibility when compared to the smooth Bv36 kernel (P=0.01). 3D VIE was successfully generated in all of the datasets with clear visualization of intraluminal views of the stents in relation to the coronary wall.

conclusionsThis preliminary report shows the feasibility of using 3D printed coronary artery models in coronary stenting for investigation of optimal coronary CT angiography protocols. Future studies should focus on placement of more stents with a range of stent diameters in the quest to reduce the need for invasive angiography for surveillance.

Indexed as

Coronary stentdiameterkernellumenmodelthree-dimensional (3D) printingvisibilityvisualization

Identifiers

PMID31559165
PMCPMC6732059
OpenAlexW2959410196

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.