ArticleMaterials (Basel, Switzerland)2019
Forces Causing One-Millimeter Displacement of Bone Fragments of Condylar Base Fractures of the Mandible after Fixation by All Available Plate Designs.
Article in Materials (Basel, Switzerland), 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 15 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
15 citing papers in PubMed, 20 citations in OpenAlex.
- Biomechanical comparison of three-dimensional titanium and CFR-PEEK plates for mandibular subcondylar fracture fixation: a three-dimensional finite element analysis.BMC oral health · 2026Article
- Effectiveness of Open Rigid Internal Fixation of Condylar Fracture Resulting in Temporomandibular Joint Function Recovery.Dentistry journal · 2025Article
- Plate Breakage After Mandibular Condylar Fracture Osteosynthesis.Journal of functional biomaterials · 2025Article
- Salivary Fistula as a Complication After the ORIF of a Mandibular Condylar Process Fracture: A Single-Centre Retrospective Study.Journal of functional biomaterials · 2025Article
- Risk of Permanent Dysfunction of Facial Nerves After Open Rigid Internal Fixation in the Treatment of Mandibular Condylar Process Fracture.Medical sciences (Basel, Switzerland) · 2025Article
- Optimal Plate Choice for High-Neck Mandibular Condyle Fracture: A Mechanistic Analysis of 16 Options.Journal of clinical medicine · 2024Article
- Open surgical approach to fractures of the mandibular condyle: surgical technique and associated complications.Turkish journal of medical sciences · 2024Article
- Which of the 37 Plates Is the Most Mechanically Appropriate for a Low-Neck Fracture of the Mandibular Condyle? A Strength Testing.Journal of clinical medicine · 2023Article
- Which of 51 Plate Designs Can Most Stably Fixate the Fragments in a Fracture of the Mandibular Condyle Base?Journal of clinical medicine · 2023Article
- Evaluation of the Relationship of Screw Pullout and Plate Fracutre in Fixation of Mandible Condyle Fractures: A Mechanistic Study.Journal of clinical medicine · 2023Article
- The Use of Titanium 3D Mini-Plates in the Surgical Treatment of Fractures of the Mandibular Condyle: A Systematic Review and Meta-Analysis of Clinical Trials.Journal of clinical medicine · 2021Review
- Condylar Neck and Sub-Condylar Fractures: Surgical Consideration and Evolution of the Technique with Short Follow-Up on Five Cases.Dentistry journal · 2020Article
- The Use of 3D Titanium Miniplates in Surgical Treatment of Patients with Condylar Fractures.Journal of clinical medicine · 2020Article
- Open Rigid Internal Fixation of Low-Neck Condylar Fractures of the Mandible: Mechanical Comparison of 16 Plate Designs.Materials (Basel, Switzerland) · 2020Article
- Mechanical Evaluation of Titanium Plates for Osteoesynthesis High Neck Condylar Fracture of Mandible.Materials (Basel, Switzerland) · 2020Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors at 1 institution in 1 country.
Funding
Abstract
backgroundThere has been no direct comparison of all existing plates dedicated for fracture osteosynthesis of mandibular condyle base until now. The aim of the study was to test mechanically all available designs of titanium plates on the market on polyurethane mandibles using an individually designed clamping system.
methodsForces required for a 1 mm displacement of fixed fracture and incidents of screw loosening were recorded. Results indicated the best mechanical plates among all existing designs available.
resultsIt has occured that some of osseofixation plates should not be used any more, whereas some shape of the single plates are similar shape to two single plates shape are regarded as the best osseofixation method for condyle base fracture.
conclusionGeneral observation is the bigger plate and more screws, the better rigid stable osteosynthesis of mandibular condyle base. 4 plates of current designs of total 30 tested series can be recommended for open rigid internal fixation of fractures of the base of the mandibular condyle. The rest of 26 existing plates should not be used in condylar base fractures.