Evidence map›Paper›PMID 31557251›Full record

ArticlePloS one2019

Surgical approach for complete cochlear coverage in EAS-patients after residual hearing loss.

Nora M Weiss, Anandhan Dhanasingh, Sebastian P Schraven, Marko Schulze, Soenke Langner, Robert Mlynski

Open access · goldAbstract read
In one paragraph

Article in PloS one, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
0.4field-weighted citation impact, top 40% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 4 citations in OpenAlex.

  1. Noise exposure of the inner ear during robotic drilling.European archives of oto-rhino-laryngology : official journal of the European Federation of Oto-Rhino-Laryngological Societies (EUFOS) : affiliated with the German Society for Oto-Rhino-Laryngology - Head and Neck Surgery · 2025
    Article
  2. Article
  3. Article
  4. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 2 institutions in 2 countries.

Nora M WeissDept. of Otorhinolaryngology, Head and Neck Surgery,"Otto Koerner"Rostock University Medical Center, Rostock, Germany.ORCID 0000-0002-0645-3591
Anandhan DhanasinghMED-EL, Innsbruck, Austria.
Sebastian P SchravenDept. of Otorhinolaryngology, Head and Neck Surgery,"Otto Koerner"Rostock University Medical Center, Rostock, Germany.
Marko SchulzeRostock University Medical Center, Institute of Anatomy Gertrudenstraße, Rostock, Germany.
Soenke LangnerInstitute of Diagnostic and Interventional Radiology, Pediatric and Neuroradiology, Rostock University Medical Center, Rostock, Germany.
Robert MlynskiDept. of Otorhinolaryngology, Head and Neck Surgery,"Otto Koerner"Rostock University Medical Center, Rostock, Germany.ORCID 0000-0001-6404-6364
University of Rostock · DEMED-EL (Austria) · AT

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

introductionIn cases with residual-hearing (RH) loss after cochlear implantation, a safe method is needed to provide full spectral resolution and as much auditory information as possible without implant replacement. Aim of this study was to prove the feasibility of accessing a partially inserted cochlear-implant-electrode for complete insertion to its maximum length through the external ear canal using a transcanal approach.

methodsTwo CI electrodes were customized with 18 stimulating channels. The electrode design enables the use of 12 active channels available for electrical stimulation inside the cochlea both after partial and full insertion. 10 CI electrodes were implanted in 10 fresh human cadaveric temporal bones. After initial partial insertion by posterior tympanotomy, the electrode was inserted to its maximum length via a transcanal approach. Radiographs and CT scans were performed to confirm the electrode position. The electrodes were investigated via x-ray after removal.

resultsX-ray and CT-scans confirmed the electrode prototypes covering an angular insertion depth between 236° to 307° after initial insertion. Accessing the electrode in the middle ear space was feasible and insertion to its full length was successful. Post-insertion CT confirmed insertion of the 28mm and 31.5mm electrode arrays covering an angular insertion depth between 360° and 540° respectively. No tip foldovers were detected.

conclusionThis study confirms the feasibility of extending the electrode insertion to its maximum insertion length using a transcanal approach in temporal bone specimens. This constitutes a second stage procedure on demand in EAS-surgery. This may be beneficial for EAS-patients providing electrical stimulation beyond the basal turn of the cochlea once the functional residual hearing is lost, without replacing the entire CI.

Indexed as

Cochlear ImplantsElectrodes, ImplantedAcoustic StimulationCochleaCochlear ImplantationElectric Stimulation TherapyEquipment DesignFeasibility StudiesHearing LossHumansTomography, X-Ray Computed

Identifiers

PMID31557251
PMCPMC6762079
OpenAlexW2975699951

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.