Evidence map›Paper›PMID 31557174›Full record

ArticlePloS one2019

Predicting spinal profile using 3D non-contact surface scanning: Changes in surface topography as a predictor of internal spinal alignment.

J Paige Little, Lionel Rayward, Mark J Pearcy, Maree T Izatt, Daniel Green, Robert D Labrom, Geoffrey N Askin

Open access · goldAbstract read
In one paragraph

Article in PloS one, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 9 papers.

0numbers the graph read from it
0cells of the map it votes in
9citing papers in PubMed
0.6field-weighted citation impact, top 34% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

9 citing papers in PubMed, 17 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Observational
  5. Article
  6. Article
  7. Article
  8. Article
  9. Assessment of the reliability of hand-held surface scanner in the evaluation of adolescent idiopathic scoliosis.European spine journal : official publication of the European Spine Society, the European Spinal Deformity Society, and the European Section of the Cervical Spine Research Society · 2021
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 2 institutions in 1 country.

J Paige LittleBiomechanics and Spine Research Group, Institute of Health and Biomedical Innovation, Queensland University of Technology, Brisbane, Australia.ORCID 0000-0001-8377-5343
Lionel RaywardBiomechanics and Spine Research Group, Institute of Health and Biomedical Innovation, Queensland University of Technology, Brisbane, Australia.
Mark J PearcyBiomechanics and Spine Research Group, Institute of Health and Biomedical Innovation, Queensland University of Technology, Brisbane, Australia.ORCID 0000-0002-1108-6503
Maree T IzattBiomechanics and Spine Research Group, Institute of Health and Biomedical Innovation, Queensland University of Technology, Brisbane, Australia.ORCID 0000-0002-4926-3077
Daniel GreenSealy of Australia, Wacol, Australia.
Robert D LabromBiomechanics and Spine Research Group, Institute of Health and Biomedical Innovation, Queensland University of Technology, Brisbane, Australia.
Geoffrey N AskinBiomechanics and Spine Research Group, Institute of Health and Biomedical Innovation, Queensland University of Technology, Brisbane, Australia.
Queensland University of Technology · AUMater Health Services · AU

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

introduction3D non-contact surface scanners capture highly accurate, calibrated images of surface topography for 3D structures. This study sought to establish the efficacy and accuracy of using 3D surface scanning to characterise spinal curvature and sagittal plane contour.

methods10 healthy female adults with a mean age of 25 years, (standard deviation: 3.6 years) underwent both MRI and 3D surface scanning (3DSS) (Artec Eva, Artec Group Inc., Luxembourg) while lying in the lateral decubitus position on a rigid substrate. Prior to 3DSS, anatomical landmarks on the spinous processes of each participant were demarcated using stickers attached to the skin surface. Following 3DSS, oil capsules (fiducial markers) were overlaid on the stickers and the subject underwent MRI. MRI stacks were processed to measure the thoracolumbar spinous process locations, providing an anatomical reference. 3D coordinates for the markers (surface stickers and MRI oil capsules) and for the spinous processes mapped the spinal column profiles and were compared to assess the quality of fit between the 3DSS and MRI marker positions.

resultsThe RMSE for the polynomials fit to the spinous process, fiducial and surface marker profiles ranged from 0.17-1.15mm for all subjects. The MRI fiducial marker location was well aligned with the spinous process profile in the thoracic and upper lumbar spine for nine of the subjects. Over the 10 subjects, the mean RMSE between the MRI and 3D scan sagittal profiles for all surface markers was 9.8mm (SD 4.2mm). Curvature was well matched for seven of the subjects, with two showing differing curvatures across the lumbar spine due to inconsistent subject positioning.

conclusionComparison of the observed trends for vertebral position measured from MRI and 3DSS, suggested the surface markers may provide a useful method for measuring internal changes in sagittal curvature or skeletal changes.

Indexed as

Magnetic Resonance ImagingAdultAnatomic LandmarksBackFemaleHumansImaging, Three-DimensionalSpinal CurvaturesSpine

Identifiers

PMID31557174
PMCPMC6762190
OpenAlexW2976866096

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.