Evidence map›Paper›PMID 31555674›Full record

ArticleFrontiers in veterinary science2019

Abnormal Curtain Signs Identified With a Novel Lung Ultrasound Protocol in Six Dogs With Pneumothorax.

Søren Boysen, Jantina McMurray, Kris Gommeren

Open access · goldAbstract readCase Reports
In one paragraph

Article in Frontiers in veterinary science, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 14 papers.

0numbers the graph read from it
0cells of the map it votes in
14citing papers in PubMed
2.0field-weighted citation impact, top 14% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

14 citing papers in PubMed, 32 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Review
  7. Feline friendly POCUS: how to implement it into your daily practice.Journal of feline medicine and surgery · 2024
    Review
  8. Basic triage in dogs and cats: Part I.The Canadian veterinary journal = La revue veterinaire canadienne · 2024
    Review
  9. Article
  10. Article
  11. Article
  12. Article
  13. Article
  14. Point-of-Care Ultrasound and Clinical Findings in 14 Cats With High-Rise Syndrome.Journal of veterinary emergency and critical care (San Antonio, Tex. : 2001)
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors at 2 institutions in 2 countries.

Søren BoysenDepartment of Veterinary Clinical and Diagnostic Sciences, Faculty of Veterinary Medicine, University of Calgary, Calgary, AB, Canada.
Jantina McMurrayDepartment of Veterinary Clinical and Diagnostic Sciences, Faculty of Veterinary Medicine, University of Calgary, Calgary, AB, Canada.
Kris GommerenFaculty of Veterinary Medicine, University of Liège, Liège, Belgium.
University of Calgary · CAUniversity of Liège · BE

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Pneumothorax is typically ruled out sonographically by detecting a glide sign, lung pulse, and/or B lines, and ruled in by detecting the return of a glide sign and/or presence of a lung point. This case series describes novel lung ultrasound findings (abnormal curtain signs) in dogs with naturally-occurring pneumothorax. This case series also describes a novel lung ultrasound protocol that involves evaluating the curtain sign along the entire thoracoabdominal border and evaluating the ventral pleural space with the probe parallel to the ribs. Six dogs with pneumothorax (three traumatic pneumothorax and three spontaneous pneumothorax) had lung ultrasound performed. All dogs had normal synchronous curtain signs in the caudal mid-to-ventral region of the thorax and abnormal curtain signs in the caudal mid-to-dorsal thoracic regions. Five dogs had bilateral pneumothorax; four had a lung point and absence of a glide sign bilaterally, and one had a lung point identified unilaterally (a lung point was not visible on the opposite side and the glide sign was equivocal bilaterally). One dog had a unilateral pneumothorax, in which a lung point and absence of a glide sign were identified. With the probe parallel to the ribs in the ventral thorax, a small volume pleural effusion was also identified in two dogs. All dogs had mild to moderate quantities of pleural air removed via thoracentesis or chest tubes following lung ultrasound. Two distinct types of abnormal curtain sign were observed, referred to as the asynchronous curtain sign and the double curtain sign. The authors hypothesize that these abnormal curtain signs are caused by the presence of free air within and/or cranial to the costophrenic recess. To the authors' knowledge, this is the first description of pneumothorax-induced abnormal curtain signs, and the first report of evaluating the curtain sign to diagnose pneumothorax in any species. Further research is required to determine the sensitivity and specificity of asynchronous and double curtain signs in diagnosing pneumothorax, and to investigate whether probe orientation parallel to the ribs in the ventral thorax will improve detection of pleural effusion.

Indexed as

curtain signFASTlung ultrasoundpneumothoraxpoint of care ultrasound

Identifiers

PMID31555674
PMCPMC6722189
OpenAlexW2967356872

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.