ArticlePloS one2019
A novel strategy for interpreting the T-SPOT.TB test results read by an ELISPOT plate imager.
Article in PloS one, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers, 1 of them a synthesis that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
3 citing papers in PubMed, 1 synthesis or guideline pooled it.
- Use of T Cell Mediated Immune Functional Assays for Adjustment of Immunosuppressive or Anti-infective Agents in Solid Organ Transplant Recipients: A Systematic Review.Frontiers in immunology · 2020Pooled it
- Role of interferon-gamma release assay for screening and monitoring of latent tuberculosis infection in kidney transplant recipients.BMC infectious diseases · 2024Article
- Evaluation of a New Chemiluminescent Immunoassay-Based Interferon-Gamma Release Assay for Detection of Latent Tuberculosis Infection.Medicina (Kaunas, Lithuania) · 2023Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundThe T-SPOT.TB can be read by an ELISPOT plate imager as an alternative to a labor-intensive and time-consuming manual reading, but its accuracy has not been sufficiently discussed to date.
methods1,423 test results obtained from manual reading using a microscope and an ELISPOT plate imager were compared. The agreement of qualitative test results was assessed using Cohen's kappa coefficient. The relationship of spot counts was studied using Bland-Altman analysis.
resultsThe overall percent agreement of the qualitative test results was 95.43% with a kappa coefficient of 0.91. Positive test results with the maximum net spot count of 8 and borderline test results showed relatively high discordance. The agreement of spot counts in panel A, panel B, and nil control was good, and variability did not increase with higher spot counts. On the basis of study findings, a novel strategy for interpreting the test results by an ELISPOT plate imager was proposed.
conclusionsTo increase diagnostic accuracy, positive test results with the maximum net spot count of 8 and borderline test results should be manually confirmed. Our strategy could be a practical guide for laboratories to build their own strategies for interpreting the test results by an ELISPOT plate imager.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials