SynthesisJournal of the American Heart Association2019
Three-Dimensional Echocardiography for Transcatheter Aortic Valve Replacement Sizing: A Systematic Review and Meta-Analysis.
Synthesis in Journal of the American Heart Association, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 21 papers, 2 of them syntheses that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
21 citing papers in PubMed, 2 syntheses or guidelines pooled it.
- Comparison of postoperative outcomes following multidetector computed tomography based vs transesophageal echocardiography based annulus sizing for transcatheter aortic valve replacement: A systematic review and meta-analysis.Echocardiography (Mount Kisco, N.Y.) · 2020Pooled it
- Three-Dimensional Echocardiography for Transcatheter Aortic Valve Replacement Sizing: A Systematic Review and Meta-Analysis.Journal of the American Heart Association · 2019Pooled it
- Multimodality echocardiography in structural heart disease: the evolving role of the interventional imager.European heart journal. Imaging methods and practice · 2026Review
- Contemporary Management of the Aortic Valve-Narrative Review of an Evolving Landscape.Journal of clinical medicine · 2024Review
- Aortic regurgitation: from mechanisms to management.EuroIntervention : journal of EuroPCR in collaboration with the Working Group on Interventional Cardiology of the European Society of Cardiology · 2024Review
- Perioperative 3D transoesophageal echocardiography. Part 2: clinical applications.BJA education · 2024Review
- Saudi Heart Association/National Heart Center/Saudi Arabian Cardiac Interventional Society/Saudi Society for Cardiac Surgeons/Saudi Cardiac Imaging Group 2023 TAVI Guidelines.Journal of the Saudi Heart Association · 2024Article
- Transcatheter aortic valve replacement: Past, present, and future.Clinical cardiology · 2024Review
- Automated and semi-automated 3D echocardiographic software for aortic annulus sizing in transcatheter aortic valve implantation helps bridge the gap between expert and novice operators.The international journal of cardiovascular imaging · 2023Article
- Three-Dimensional Transesophageal Echocardiography in Percutaneous Catheter-Based Cardiac Interventions.Journal of clinical medicine · 2023Review
- Echocardiographic Imaging in Transcatheter Structural Intervention: An AAE Review Paper.JACC. Asia · 2023Review
- Catheter-Based Interventions for the Management of Valvular Heart Disease During Pregnancy.JACC. Advances · 2022Review
- Preoperative TAVR Planning: How to Do It.Journal of clinical medicine · 2022Review
- Application research of three-dimensional transesophageal echocardiography in predicting prosthetic valve size for transcatheter aortic valve implantation.Annals of translational medicine · 2022Article
- Article
- Aortic Annular Sizing Using Novel Software in Three-Dimensional Transesophageal Echocardiography for Transcatheter Aortic Valve Replacement: A Systematic Review and Meta-Analysis.Diagnostics (Basel, Switzerland) · 2021Review
- Article
- The TAVR that Got Away: A Case Report.CASE (Philadelphia, Pa.) · 2020Article
- Current and Future Aspects of Multimodal Imaging, Diagnostic, and Treatment Strategies in Bicuspid Aortic Valve and Associated Aortopathies.Journal of clinical medicine · 2020Review
- White paper on mitigating risk factors for acute kidney injury in TAVR: A protocol to decrease TAVR-associated AKI.Indian heart journalArticle
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
12 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Background Transcatheter aortic valve replacement (TAVR) is the standard of care for many patients with severe symptomatic aortic stenosis and relies on accurate sizing of the aortic annulus. It has been suggested that 3-dimensional transesophageal echocardiography (3D TEE) may be used instead of multidetector computed tomography (MDCT) for TAVR planning. This systematic review and meta-analysis compared 3D TEE and MDCT for pre-TAVR measurements. Methods and Results A systematic literature search was performed. The primary outcome was the correlation coefficient between 3D TEE- and MDCT-measured annular area. Secondary outcomes were correlation coefficients for mean annular diameter, annular perimeter, and left ventricular outflow tract area; interobserver and intraobserver agreements; mean differences between 3D TEE and MDCT measurements; and pooled sensitivities, specificities, and receiver operating characteristic area under curve values of 3D TEE and MDCT for discriminating post-TAVR paravalvular aortic regurgitation. A random effects model was used. Meta-regression and leave-one-out analysis for the primary outcome were performed. Nineteen studies with a total of 1599 patients were included. Correlations between 3D TEE and MDCT annular area, annular perimeter, annular diameter, and left ventricular outflow tract area measurements were strong (0.86 [95% CI, 0.80-0.90]; 0.89 [CI, 0.82-0.93]; 0.80 [CI, 0.70-0.87]; and 0.78 [CI, 0.61-0.88], respectively). Mean differences between 3D TEE and MDCT between measurements were small and nonsignificant. Interobserver and intraobserver agreement and discriminatory abilities for paravalvular aortic regurgitation were good for both 3D TEE and MDCT. Conclusions For pre-TAVR planning, 3D TEE is comparable to MDCT. In patients with renal dysfunction, 3D TEE may be potentially advantageous for TAVR measurements because of the lack of contrast exposure.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.