ArticleSensors (Basel, Switzerland)2019
On-Orbit Signal-to-Noise Ratio Test Method for Night-Light Camera in Luojia 1-01 Satellite Based on Time-Sequence Imagery.
Article in Sensors (Basel, Switzerland), 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
3 authors.
Funding
Abstract
Night-light remote sensing imaging technologies have increasingly attracted attention with the development and application of focal plane arrays. On-orbit signal-to-noise ratio (SNR) test is an important link to evaluate night-light camera's radiometric performance and the premise for quantitative application of remote sensing imageries. Under night-light illumination conditions, the illuminance of ground objects is very low and varies dramatically, the spatial uniformity of each pixel's output cannot be guaranteed, and thus the traditional on-orbit test methods represented by variance method are unsuitable for low-resolution night-light cameras. To solve this problem, we proposed an effective on-orbit SNR test method based on consecutive time-sequence images that including the same objects. We analyzed the radiative transfer process between night-light camera and objects, and established a theoretical SNR model based on analysis of the generation and main sources of signal electrons and noise electrons. Finally, we took Luojia 1-01 satellite, the world's first professional night-light remote sensing satellite, as reference and calculated the theoretical SNR and actual on-orbit SNR using consecutive images captured by Luojia 1-01 satellite. The actual results show the similar characteristics as theoretical results, and are higher than the theoretical results within the reasonable error tolerance, which fully guarantee the detection ability of night-light camera and verify the validity of this time-sequence-based method.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.