ArticleSensors (Basel, Switzerland)2019
Thin Magnetically Permeable Targets for Inductive Sensing: Application to Limb Prosthetics.
Article in Sensors (Basel, Switzerland), 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
8 citing papers in PubMed.
- An Inductive Sensing System for Optimizing Prosthetic Socket Fit.Sensors (Basel, Switzerland) · 2026Article
- Frequent versus infrequent partial doffing in transtibial prosthesis users as a means to stabilize residual limb fluid volume.Clinical biomechanics (Bristol, Avon) · 2025Article
- A novel portable sensor to monitor bodily positions and activities in transtibial prosthesis users.Clinical biomechanics (Bristol, Avon) · 2022Article
- A Prosthetic Socket with Active Volume Compensation for Amputated Lower Limb.Sensors (Basel, Switzerland) · 2021Article
- Modeling the mechanics of elevated vacuum systems in prosthetic sockets.Medical engineering & physics · 2020Article
- Incorporating a Ferrous Polymer Target into Elastomeric Liners for Socket Fit Sensing in Prosthesis Users.Sensors (Basel, Switzerland) · 2020Article
- Performance of an auto-adjusting prosthetic socket during walking with intermittent socket release.Journal of rehabilitation and assistive technologies engineeringArticle
- Testing an adjustable prosthetic socket in a simulated military environment.Journal of rehabilitation and assistive technologies engineeringArticle
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
8 authors.
Funding
Abstract
The purpose of this research was to create a thin ferrous polymer composite to be used as a target for inductive sensing in limb prosthetics. Inductive sensors are used to monitor limb-to-socket distance in prosthetic sockets, which reflects socket fit. A styrene-ethylene-ethylene/propylene-styrene (SEEPS) polymer was mixed with iron powder at three concentrations (75, 77, 85 wt%), and thin disk-shaped samples were fabricated (0.50, 0,75, 1.00 mm thickness). For 85 wt% samples of 0.50 mm thickness, which proved the best combination of high signal strength and low target volume, inductive sensor sensitivity ranged from 3.2E5 counts/mm at 0.00-1.00 mm distances to 7.2E4 counts/mm at 4.00-5.00 mm distances. The application of compressive stress (up to 425 kPa) introduced an absolute measurement error of less than 3.3 μm. Tensile elasticity was 282 kPa, which is comparable to that of commercial elastomeric liners. Durability testing in the shoe of an able-bodied participant demonstrated a change in calibration coefficient of less than 3.8% over two weeks of wear. The ferrous polymer composite may facilitate the development of automatically adjusting sockets that use limb-to-socket distance measurement for feedback control.