Observational studyIndian journal of ophthalmology2019
Evaluation of the vitreous chamber depth: An assessment of correlation with ocular biometrics.
Observational study in Indian journal of ophthalmology, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 13 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
13 citing papers in PubMed.
- Splicing variants in MYRF cause partial loss of function in the retinal pigment epithelium leading to nanophthalmos.JCI insight · 2026Article
- Correlation of the crystalline lens thickness and ocular parameters in young and middle-aged myopes grouped by axial length.BMC ophthalmology · 2025Article
- The Ocular Parameter Changes Caused by Reading With Remote Image Optical Screen.Translational vision science & technology · 2025Article
- Updated study on demographic and ocular biometric characteristics of cataract patients indicates new trends in cataract surgery.Scientific reports · 2025Article
- Refraction and ocular biometric parameters in 3-to 6-year-old preschool children : a large-scale population-based study in Chengdu, China.BMC ophthalmology · 2024Article
- Central anterior chamber depth correlated with white-to-white distance in normal, long, and short eyes.International ophthalmology · 2024Article
- Congenital Malformations of the Eye: A Pictorial Review and Clinico-Radiological Correlations.Journal of ophthalmology · 2024Review
- Nonlinear pathological trajectory of a high-myopia C57/BL6J mouse model induced by form deprivation.Frontiers in physiology · 2024Article
- Mendelian randomization study confirms causal relationship between myopia and vitreous disorders.BMC medical genomics · 2023Article
- Residual refractive errors in pseudophakic eyes and related factors: a population-based study.International journal of ophthalmology · 2023Article
- Correlation of vitreous chamber depth with ocular biometry in high axial myopia.Indian journal of ophthalmology · 2022Article
- Analysis of Lens Thickness Distribution Based on Swept-Source Optical Coherence Tomography (SS-OCT).Journal of ophthalmology · 2021Article
- The Effect of Ambient Light Intensity on Transient Changes in Refraction and Ocular Biometric Components following Near Work: A Randomized Clinical Trial.Journal of current ophthalmologyArticle
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Purpose: The mechanism of ocular growth eludes us and research on vitreous chamber depth (VCD) is lacking. The purpose of this study was to evaluate the role of VCD and its ratio to axial length (AL) in relation to ocular biometry. Methods: This retrospective study of patients planned for cataract surgery was performed at a tertiary center. Data regarding AL, anterior chamber depth (ACD), lens thickness (LT), and central corneal thickness (CCT) of 640 eyes was noted. Anterior segment (AS) was measured as sum of CCT, ACD, and LT, while VCD was calculated as the difference between AL and AS. Correlation of VCD and VCD: AL with ocular biometry was the primary outcome measure. Three groups were formed on the basis of AL and Pearson correlation coefficient (R) was applied. Results: Mean VCD was 15.38+/-1.14 mm. Mean VCD: AL was 0.66+/-0.02. VCD had a very strong relation with AL (R = 0.9, P < 0.001) only, whereas VCD: AL had a good--strong relation with AL (R = 0.5, P < 0.001), AS (R = 0.7, P < 0.001), ACD (R = 0.3, P < 0.001), and LT (R = 0.5, P < 0.001). The relation of VCD: AL with AS was very strong across all groups (R ≤ -0.8, P < 0.001 in all groups). 85% of eyes in group with AL <22 mm had VCD: AL <0.67, conversely 85% of eyes with AL >24.5 mm had VCD: AL >0.67. Conclusion: : We found VCD to have the strongest relation with AL. VCD: AL was more consistent and showed a strong relation to ocular biometry across all ALs. This suggests the possible utility of the ratio VCD: AL while evaluating ocular growth, refractive status, and myopia-related complications.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.