Evidence map›Paper›PMID 31542570›Full record

ArticleJournal of the mechanical behavior of biomedical materials2020

An investigation of the effect of freezing storage on the biaxial mechanical properties of excised porcine tricuspid valve anterior leaflets.

Grace A Duginski, Colton J Ross, Devin W Laurence, Cortland H Johns, Chung-Hao Lee

Abstract read
In one paragraph

Article in Journal of the mechanical behavior of biomedical materials, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 21 papers.

0numbers the graph read from it
0cells of the map it votes in
21citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

21 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Article
  10. Article
  11. Article
  12. Article
  13. Article
  14. Article
  15. Article
  16. Article
  17. Article
  18. Article
  19. Article
  20. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Grace A DuginskiBiomechanics and Biomaterials Design Laboratory (BBDL), School of Aerospace and Mechanical Engineering, The University of Oklahoma, Norman, OK, 73019, USA. Electronic address: duginskiga@ou.edu.
Colton J RossBiomechanics and Biomaterials Design Laboratory (BBDL), School of Aerospace and Mechanical Engineering, The University of Oklahoma, Norman, OK, 73019, USA. Electronic address: cjross@ou.edu.
Devin W LaurenceBiomechanics and Biomaterials Design Laboratory (BBDL), School of Aerospace and Mechanical Engineering, The University of Oklahoma, Norman, OK, 73019, USA. Electronic address: dwlaur@ou.edu.
Cortland H JohnsBiomechanics and Biomaterials Design Laboratory (BBDL), School of Aerospace and Mechanical Engineering, The University of Oklahoma, Norman, OK, 73019, USA. Electronic address: Cortland.H.Johns-1@ou.edu.
Chung-Hao LeeBiomechanics and Biomaterials Design Laboratory (BBDL), School of Aerospace and Mechanical Engineering, The University of Oklahoma, Norman, OK, 73019, USA; Institute for Biomedical Engineering, Science and Technology, School of Aerospace and Mechanical Engineering (IBEST), The University of Oklahoma, Norman, OK, 73019, USA. Electronic address: ch.lee@ou.edu.

Funding

American Heart Association-American Stroke Association 16SDG27760143
6 · The paper itself

Abstract

The atrioventricular heart valve (AHV) leaflets are critical to the facilitation of proper unidirectional blood flow through the heart. Previously, studies have been conducted to understand the tissue mechanics of healthy AHV leaflets to inform the development of valve-specific computational models and replacement materials for use in diagnosing and treating valvular heart disease. Generally, these studies involved biaxial mechanical testing of the AHV leaflet tissue specimens to extract relevant mechanical properties. Most of those studies considered freezing-based storage systems based on previous findings for other connective tissues such as aortic tissue or skin. However, there remains no study that specifically examines the effects of freezing storage on the characterized mechanical properties of the AHV leaflets. In this study, we aimed to address this gap in knowledge by performing biaxial mechanical characterizations of the tricuspid valve anterior leaflet (TVAL) tissue both before and after a 48-h freezing period. Primary findings of this study include: (i) a statistically insignificant change in the tissue extensibilities, with the frozen tissues being slightly stiffer and more anisotropic than the fresh tissues; and (ii) minimal variations in the stress relaxation behaviors between the fresh and frozen tissues, with the frozen tissues demonstrating slightly lessened relaxation. The findings from this study suggested that freezing-based storage does not significantly impact the observed mechanical properties of one of the five AHV leaflets-the TVAL. The results from this study are useful for reaffirming the experimental methodologies in the previous studies, as well as informing the tissue preservation methods of future investigations of AHV leaflet mechanics.

Indexed as

CryopreservationMechanical PhenomenaAnimalsBiomechanical PhenomenaSwineTricuspid ValveBiaxial mechanical testingFreezing storage effectsHeart valve biomechanicsStress relaxationThe tricuspid valve

Identifiers

PMID31542570
PMCPMC8008703

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.