ArticleJournal of medical ultrasonics (2001)2020
A novel adaptive apodization to improve the resolution of phased subarray imaging in medical ultrasound.
Article in Journal of medical ultrasonics (2001), 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed, 3 citations in OpenAlex.
- On the publication of the special feature on recent progress in basic research useful for the interpretation of ultrasound diagnostic images.Journal of medical ultrasonics (2001) · 2021Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
2 authors at 1 institution in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
purposePhased subarray imaging (PSA) was previously proposed to extend the receive aperture length. Using overlapped subarrays as transmitters in PSA leads to decrement of sidelobe levels of the overall beam compared to full phased array imaging (PHA). This paper proposes an adaptive compounding of subarray images in PSA to improve both the resolution and contrast compared with PHA.
methodAdaptive apodization (ADAP) is defined proportional to the beamformed responses of subarrays such that the overall energy after compounding is minimized.
resultsThe simulation and experimental results validate the performance of applying ADAP in PSA. The full width at half maximum (FWHM) at a depth of 30 mm in the proposed PSA is about 0.2 mm, compared to a FWHM of 0.6 mm with PHA imaging. Measuring the contrast ratio index shows that the ADAP method also improves the contrast in PSA imaging at least 25% compared to PHA imaging.
conclusionApplying the proposed ADAP, besides conventional compounding in PSA imaging, leads to improvement of both the resolution and contrast compared to PHA imaging.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials