Evidence map›Paper›PMID 31540322›Full record

ArticleSensors (Basel, Switzerland)2019

Novel Drift Reduction Methods in Foot-Mounted PDR System.

Wenchao Zhang, Dongyan Wei, Hong Yuan

Open access · goldAbstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
1.6field-weighted citation impact, top 16% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 19 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors at 1 institution in 1 country.

Wenchao ZhangUniversity of Chinese Academy of Sciences, Beijing100094, China. zhangwenchao@aoe.ac.cn.
Dongyan WeiAerospace Information Research Institute, Chinese Academy of Sciences, Beijing 100094, China. weidongyan@aoe.ac.cn.
Hong YuanAerospace Information Research Institute, Chinese Academy of Sciences, Beijing 100094, China. yuanhong@aircas.ac.cn.
Chinese Academy of Sciences · CN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The zero-velocity update (ZUPT)-aided extended Kalman filter (EKF) is commonly used in the traditional inertial navigation system (INS)-based foot-mounted pedestrian dead reckoning (PDR) system, which can effectively suppress the error growth of the inertial-based pedestrian navigation systems. However, in the realistic test, the system still often suffers from drift, which is commonly caused by two reasons: failed detection of the stationary phase in the dynamic pedestrian gait and heading drift, which is a poorly observable variable of the ZUPT method. In this paper, firstly, in order to improve the initial heading alignment accuracy, a novel method to calibrate the PDR system's initial absolute heading is proposed which is based on the geometric method. By using a calibration line rather than only using the heading of the starting point, the method can calibrate the initial heading of the PDR system more accurately. Secondly, for the problem of failed detection of the stationary phase in the dynamic pedestrian gait, a novel stationary phase detection method is proposed, which is based on foot motion periodicity rather than the threshold comparison principle in the traditional method. In an experiment, we found that the zero-speed state points always occur around the minimum value of the stationary detector in each gait cycle. By taking the minimum value in each gait cycle as the zero-speed state point, it can effectively reduce the failed detection of the zero-speed interval. At last, in order to reduce the heading drifts during walking over time, a new motion constraint method is exploited based on the range constraint principle. During pedestrian walking, the distance between the foot position estimates of the current moment and the previous stationary period is within the maximum stride length. Once the distance is greater than the maximum stride length, the constraint method is used to confine the current estimated foot position to the sphere of the maximum stride length relative to the previous stationary foot position. Finally, the effectiveness of all proposed methods is verified by the experiments.

Indexed as

foot-mounted PDRinitial heading calibrationrange constraintstationary phase detectionZUPT-aided EKF

Identifiers

PMID31540322
PMCPMC6766805
OpenAlexW2972835939

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.