Improving treatment efficiency via photon optimizer (PO) MLC algorithm for synchronous single-isocenter/multiple-lesions VMAT lung SBRT.

Lana Sanford, Damodar Pokhrel

Abstract read
In one paragraph

Article in Journal of applied clinical medical physics, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.

0numbers the graph read from it
0cells of the map it votes in
8citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

8 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Evaluation of improvements in plan quality with Photon Optimizer v16.1 for single brain lesion SRS treatment.Reports of practical oncology and radiotherapy : journal of Greatpoland Cancer Center in Poznan and Polish Society of Radiation Oncology · 2023
    Article
  5. Article
  6. Article
  7. Article
  8. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

2 authors.

Lana SanfordMedical Physics Graduate Program, University of Kentucky, Lexington, KY, USA.
Damodar PokhrelMedical Physics Graduate Program, University of Kentucky, Lexington, KY, USA.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeElderly patients with multiple primary or oligometastases (<5 lesions) lesions with associated co-morbidities may not retain their treatment position for the traditional long SBRT treatment time with individual isocenters for each lesion. Treating multiple lesions synchronously using a single-isocenter volumetric arc therapy (VMAT) plan would be more efficient with the use of the most recently adopted photon optimizer (PO) MLC algorithm and improve the patient comfort. Herein, we quantified the clinical performance of PO versus its predecessor progressive resolution optimizer (PRO) algorithm for single-isocenter/multiple-lesions VMAT lung SBRT. MATERIALS AND

methodsFourteen patients with metastatic non-small-cell lung cancer lesions (two to five, both uni- and bilateral lungs) received a highly conformal single-isocenter co/non-coplanar VMAT (2-6 arcs) SBRT treatment plan. Patients were treated with a 6X-FFF beam and Acuros algorithm with a single-isocenter placed between/among the lesions, using PO for MLC optimization. Average isocenter to tumor distance was 5.5 ± 1.9 cm. Mean combined PTV derived from 4D-CT scans was 38.7 ± 22.7 cc. Doses were 54 Gy/50 Gy in 3/5 fractions prescribed to 70%-80% isodose line so that at least 95% of the PTV receives 100% of prescribed dose. Plans were re-optimized using PRO algorithm. Plans were compared via ROTG-0915 protocol criteria for target conformity, heterogeneity and gradient indices, and dose to organs-at-risk (OAR). Additionally, total number of monitor units (MU), modulation factor (MF) and beam-on time were compared.

resultsAll plans met SBRT protocol requirements for target coverage and OAR doses. Comparison of target coverage and dose to the OAR showed no statistical significance between the two plans. PO had 1042 ± 753 (P < 0.001) less MU than PRO resulting in a beam-on time of about 0.75 ± 0.5 min (P < 0.001) less, on average. For similar dose distribution, a significant reduction of beam delivery complexity was observed with PO (average MF = 3.7 ± 0.7) vs PRO MLC algorithm (average MF = 4.4 ± 1.3) (P < 0.001).

conclusionsPO MLC algorithm improved treatment efficiency without compromising plan quality when compared to PRO algorithm for single-isocenter/multi-lesions VMAT lung SBRT. Shorter beam-on time can potentially reduce intrafraction motion errors and improve patient compliance. PO MLC algorithm is recommended for future clinical lung SBRT plan optimization.

Indexed as

AlgorithmsPhantoms, ImagingCarcinoma, Non-Small-Cell LungFour-Dimensional Computed TomographyHumansLung NeoplasmsLung Volume MeasurementsOrgans at RiskPhotonsPrognosisQuality Assurance, Health CareRadiosurgeryRadiotherapy DosageRadiotherapy, Intensity-ModulatedRadiotherapy Planning, Computer-AssistedRetrospective Studieslung SBRTMLCphoton optimizersingle-isocenter/multi-lesionsVMAT

Identifiers

PMID31538721
PMCPMC6806472

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.