Is rotation the mode of failure in pertrochanteric fractures fixed with nails? Theoretical approach and illustrative cases.
Review in European journal of orthopaedic surgery & traumatology : orthopedie traumatologie, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
6 citing papers in PubMed.
- Comparative strain‑gauge analysis of Gamma3 and Gamma3 reconstruction nails in unstable basicervical femur fractures: a pilot biomechanical study.International orthopaedics · 2026Article
- Article
- 3-year revision rates of left vs right cephalomedullary nails with a helical blade design.Irish journal of medical science · 2025Article
- Coronal shear fractures of the femoral neck: a comparison with basicervical fractures.European journal of trauma and emergency surgery : official publication of the European Trauma Society · 2023Article
- Conventional versus helical blade screw insertion following the removal of the femoral head screw: a biomechanical evaluation using trochanteric gamma 3 locking nail versus PFN antirotation.BMC musculoskeletal disorders · 2021Article
- A unique cause of Gamma 3 cut-out: A case report and literature review.Journal of clinical orthopaedics and trauma · 2021Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
purposeThe present article reviews data from biomechanical and clinical studies which indicate that rotational instability can cause failure of fixation due to the particular characteristics of the fracture, the mechanical properties of the chosen implant or flaws in surgical technique.
methodsAlthough radiographs give a similar impression in failure of fractures fixed with cephalomedullary nails, different mechanisms involving rotation of the femoral head may play a key role.
resultsThe incidence of failure in pertrochanteric fracture fixation is decreasing as implants continue to evolve. It is possible that currently reported low failure rates do not apply equally to all subtypes of this diverse group of fractures. Since the introduction of sliding hip screws, "cut-out" due to varus collapse of the proximal fracture fragment has been the only reported mode of failure.
conclusionExcessive rotation leading to eventual "cut-out" has not been adequately studied, and thus, available evidence is not sufficient to definitely prove this theoretical approach. As nailing is gradually overtaking extramedullary fixation as the treatment of choice, especially for comminuted pertrochanteric fractures which can be rotationally unstable, further research is warranted to improve our understanding of the pathogenetic mechanisms of failure.