ArticleJournal of biomedical optics2019
Single-pixel camera photoacoustic tomography.
Article in Journal of biomedical optics, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 12 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
12 citing papers in PubMed, 31 citations in OpenAlex.
- Ultrahigh-throughput single-pixel complex-field microscopy with frequency-comb acousto-optic coherent encoding (FACE).Light, science & applications · 2025Article
- Compressed Sensing for Biomedical Photoacoustic Imaging: A Review.Sensors (Basel, Switzerland) · 2024Review
- Convolutional sparse coding for compressed sensing photoacoustic CT reconstruction with partially known support.Biomedical optics express · 2024Article
- Design, implementation, and analysis of a compressed sensing photoacoustic projection imaging system.Journal of biomedical optics · 2024Article
- Compressed single-shot 3D photoacoustic imaging with a single-element transducer.Photoacoustics · 2023Article
- Dual-compressed photoacoustic single-pixel imaging.National science review · 2023Article
- Compressed sensing for photoacoustic computed tomography based on an untrained neural network with a shape prior.Biomedical optics express · 2021Article
- Sparsity-Based Recovery of Three-Dimensional Photoacoustic Images from Compressed Single-Shot Optical Detection.Journal of imaging · 2021Article
- Single pixel imaging at megahertz switching rates via cyclic Hadamard masks.Nature communications · 2021Article
- Single laser-shot super-resolution photoacoustic tomography with fast sparsity-based reconstruction.Photoacoustics · 2021Article
- Deep learning enabled real-time photoacoustic tomography system via single data acquisition channel.Photoacoustics · 2021Article
- Single-pixel imaging of dynamic objects using multi-frame motion estimation.Scientific reports · 2021Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors at 1 institution in 2 countries.
Funding
Abstract
Since it was first demonstrated more than a decade ago, the single-pixel camera concept has been used in numerous applications in which it is necessary or advantageous to reduce the channel count, cost, or data volume. Here, three-dimensional (3-D), compressed-sensing photoacoustic tomography (PAT) is demonstrated experimentally using a single-pixel camera. A large area collimated laser beam is reflected from a planar Fabry–Pérot ultrasound sensor onto a digital micromirror device, which patterns the light using a scrambled Hadamard basis before it is collected into a single photodetector. In this way, inner products of the Hadamard patterns and the distribution of thickness changes of the FP sensor—induced by the photoacoustic waves—are recorded. The initial distribution of acoustic pressure giving rise to those photoacoustic waves is recovered directly from the measured signals using an accelerated proximal gradient-type algorithm to solve a model-based minimization with total variation regularization. Using this approach, it is shown that 3-D PAT of imaging phantoms can be obtained with compression rates as low as 10%. Compressed sensing approaches to photoacoustic imaging, such as this, have the potential to reduce the data acquisition time as well as the volume of data it is necessary to acquire, both of which are becoming increasingly important in the drive for faster imaging systems giving higher resolution images with larger fields of view.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.