Evidence map›Paper›PMID 31534830›Full record

ArticleTranslational vision science & technology2019

Development of an Eye Model With a Physiological Blink Mechanism.

Chau-Min Phan, Hendri Walther, Ha Qiao, Ra Shinde, Lyndo Jones

Open access · goldAbstract read
In one paragraph

Article in Translational vision science & technology, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 10 papers.

0numbers the graph read from it
0cells of the map it votes in
10citing papers in PubMed
2.4field-weighted citation impact, top 11% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

10 citing papers in PubMed, 22 citations in OpenAlex.

  1. Review
  2. Article
  3. Modelling the thermal effects of stimulus airflow from the Dolphin aesthesiometer on a model eye surface.Ophthalmic & physiological optics : the journal of the British College of Ophthalmic Opticians (Optometrists) · 2025
    Article
  4. Article
  5. Article
  6. Review
  7. Article
  8. Unraveling the mechanobiology of cornea: From bench side to the clinic.Frontiers in bioengineering and biotechnology · 2022
    Review
  9. Article
  10. Role of In Vitro Models for Development of Ophthalmic Delivery Systems.Critical reviews in therapeutic drug carrier systems · 2021
    Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 2 institutions in 2 countries.

Chau-Min PhanCentre for Ocular Research & Education (CORE), School of Optometry and Vision Science, University of Waterloo, Waterloo, ON, Canada.
Hendri WaltherCentre for Ocular Research & Education (CORE), School of Optometry and Vision Science, University of Waterloo, Waterloo, ON, Canada.
Ha QiaoCentre for Ocular Research & Education (CORE), School of Optometry and Vision Science, University of Waterloo, Waterloo, ON, Canada.
Ra ShindeManipal Academy of Higher Education, Manipal Institute of Technology, Madhav Nagar, Manipal, Karnataka, India.
Lyndo JonesCentre for Ocular Research & Education (CORE), School of Optometry and Vision Science, University of Waterloo, Waterloo, ON, Canada.
University of Waterloo · CAManipal Academy of Higher Education · IN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeTo develop an eye model with a physiological blink mechanism.

methodsAll parts of the eye model were designed using computer-aided design software. The eyelid consisted of a unique 3D printed structure containing teeth to physically secure a flexible membrane. Both the eyeball and eyelid membrane were synthesized using polyvinyl alcohol (PVA). Four molecular weights of PVA (89-98, 85-124, 130, and 146-186 kDa) were tested at a range of concentrations between 5% and 30% weight/volume. The wettability and water content of these materials were compared with the bovine cornea and sclera. The model was connected to a microfluidic pump, which delivers artificial tear solution (ATS) to the eyelid. A corneal topographer was used to evaluate the tear break-up and tear film regeneration.

resultsThe eyelid flexes and slides across the eyeball during each blink, which ensures direct contact between the two surfaces. When loaded with an ATS, this mechanism evenly spreads the solution over the eyeball to generate an artificial tear film. The artificial tear film in this eye model had a tear break-up time (TBUT) of 5.13 ± 0.09 seconds at 1.4 μL/min flow rate, 6 blinks/min, and <25% humidity.

conclusionsThis model simulates a physiological blink actuation and an artificial tear film layer. Future studies will examine variations in flow rates and ATS composition to simulate clinical values of TBUT. TRANSLATIONAL RELEVANCE: The eye model could be used to study in vitro TBUT, tear deposition, and simple drug delivery.

Indexed as

blinkeye modelin vitropolyvinyl alcoholPVA

Identifiers

PMID31534830
PMCPMC6727780
OpenAlexW2971759720

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.