Benchmarking Monte-Carlo dose calculation for MLC CyberKnife treatments.
Article in Radiation oncology (London, England), 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 9 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
9 citing papers in PubMed.
- Comparative dosimetric evaluation of independent verification systems: ArcherQA versus AccuCheck for volumetric modulated Arc therapy plan validation.Radiation oncology (London, England) · 2026Article
- Evaluation of a Monte Carlo-based independent dose calculation system for brain stereotactic radiotherapy using a robotic radiosurgery system.Radiological physics and technology · 2026Article
- AAPM task group report 135.B: Quality assurance for robotic radiosurgery.Medical physics · 2025Article
- Validation of SRS MapCHECK for CyberKnife patient-specific quality assurance: challenges with small cone sizes.Frontiers in oncology · 2025Article
- Clinical application of a GPU-accelerated monte carlo dose verification for cyberknife M6 with Iris collimator.Radiation oncology (London, England) · 2024Article
- Development of a LINAC head model for the CyberKnife VSI-System using EGSnrc Monte Carlo system.Journal of applied clinical medical physics · 2023Article
- A novel Monte Carlo (MC) dose model for small MLC fields of the cyberknifeJournal of applied clinical medical physics · 2023Article
- Validation of Monte Carlo dose calculation algorithm for CyberKnife multileaf collimator.Journal of applied clinical medical physics · 2022Article
- Commissioning and clinical implementation of the first commercial independent Monte Carlo 3D dose calculation to replace CyberKnife M6™ patient-specific QA measurements.Journal of applied clinical medical physics · 2020Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
12 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundVendor-independent Monte Carlo (MC) dose calculation (IDC) for patient-specific quality assurance of multi-leaf collimator (MLC) based CyberKnife treatments is used to benchmark and validate the commercial MC dose calculation engine for MLC based treatments built into the CyberKnife treatment planning system (Precision MC).
methodsThe benchmark included dose profiles in water in 15 mm depth and depth dose curves of rectangular MLC shaped fields ranging from 7.6 mm × 7.7 mm to 115.0 mm × 100.1 mm, which were compared between IDC, Precision MC and measurements in terms of dose difference and distance to agreement. Dose distributions of three phantom cases and seven clinical lung cases were calculated using both IDC and Precision MC. The lung PTVs ranged from 14 cm
resultsAbsolute dose profiles in 15 mm depth in water showed agreement between Precision MC and IDC within 3.1% or 1 mm. Depth dose curves agreed within 2.3% / 1 mm. For the phantom and clinical lung cases, mean PTV doses differed from - 1.0 to + 2.3% between IDC and Precision MC and gamma passing rates were > =98.1% for all multiple beam treatment plans. For the lung cases, lung V20 agreed within ±1.5%. Calculation times ranged from 2.2 min (for 39 cm
conclusionsBoth accuracy and efficiency of Precision MC in the context of MLC based planning for the CyberKnife M6 system were benchmarked against MC based IDC framework. Precision MC is used in clinical practice at our institute.