Evidence map›Paper›PMID 31529257›Full record

ArticleEuropean radiology2020

Long-term experience and analysis of data on diagnostic reference levels: the good, the bad, and the ugly.

Patrice Roch, David Célier, Cécile Dessaud, Cécile Etard, Madan M Rehani

Abstract read
PubMed Publisher
In one paragraph

Article in European radiology, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 13 papers.

0numbers the graph read from it
0cells of the map it votes in
13citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

13 citing papers in PubMed.

  1. Article
  2. Review
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Article
  10. Article
  11. Review
  12. Article
  13. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Patrice RochInstitut de Radioprotection et de Sûreté Nucléaire, 31 avenue de la division Leclerc, 92260, Fontenay-aux-Roses, France. rochpr@gmail.com.ORCID http://orcid.org/0000-0001-8973-6951
David CélierInstitut de Radioprotection et de Sûreté Nucléaire, 31 avenue de la division Leclerc, 92260, Fontenay-aux-Roses, France.
Cécile DessaudCERAP, 4 rue René Razel, Domaine Technologique de Saclay, 91400, Saclay, France.
Cécile EtardInstitut de Radioprotection et de Sûreté Nucléaire, 31 avenue de la division Leclerc, 92260, Fontenay-aux-Roses, France.
Madan M RehaniMassachusetts General Hospital, Boston, MA, USA.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectivesTo analyze 11-year data of France for temporal trends in dose indices and dose optimization and draw lessons for those who are willing to work on creation and update of diagnostic reference levels (DRLs).

methodsThe data from about 3000 radiology departments leading to about 750,000 imaging exams between 2004 and 2015 was analyzed, and patterns of reductions in dose for those below and above the DRLs were estimated and correlated with technology change.

resultsDose optimization achieved was important and significant in departments which were above or just below the DRL (p = .006) but not in those which were around half of the DRL values. The decrease in 75th percentile value of Kerma air product (KAP) for chest radiography by 27.4% between 2004 and 2015 was observed with the number of flat panel detectors increase from 6 to 43%. A good correlation between the detector type distribution and the level of patient radiation exposure is observed. Otherwise, setting DRLs for standard-sized patient excludes patients lower and higher weighted than "standard."

conclusionsThe concept of DRL may become obsolete unless lessons drawn from the experience of users are taken into account. While establishing DRLs should be part of the regulations, setting up and updating values should be governed by bodies whose decision-making cycle is short, at the most 1 year. A local rather than national approach, taking into account body habitus and image quality, needs to be organized. KEY POINTS: • The technology changes faster than regulations. Requirement of DRL establishment should be part of the regulations; however, setting and updating values should be the role of professional societies. • The concept of DRL, highlighting the 75th percentile values and dedicated to standard-sized adult, misses optimization opportunities in the majority of patients who are below the 75th percentile value and outside the range of standard-sized adult. • The ugly aspects of the DRL concept include its non-applicability to individuals, no customization to clinical indications, and lack of consideration of image quality.

Indexed as

Radiation DosageAdultFemaleFranceHumansRadiation ExposureRadiographyReference ValuesTimeDiagnostic imagingPatient safetyRadiation exposureRadiation protectionReference values

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.