Evidence map›Paper›PMID 31528659›Full record

ArticleJournal of medical imaging (Bellingham, Wash.)2019

Volume-of-interest imaging with dynamic fluence modulation using multiple aperture devices.

Wenying Wang, Grace J Gang, Jeffrey H Siewerdsen, Reuven Levinson, Satomi Kawamoto, J Webster Stayman

Abstract read
In one paragraph

Article in Journal of medical imaging (Bellingham, Wash.), 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Wenying WangJohns Hopkins University, Department of Biomedical Engineering, Baltimore, Maryland, United States.ORCID https://orcid.org/0000-0002-2560-5263
Grace J GangJohns Hopkins University, Department of Biomedical Engineering, Baltimore, Maryland, United States.ORCID https://orcid.org/0000-0002-3882-0210
Jeffrey H SiewerdsenJohns Hopkins University, Department of Biomedical Engineering, Baltimore, Maryland, United States.ORCID https://orcid.org/0000-0001-6644-1317
Reuven LevinsonPhilips Healthcare, Haifa, Israel.
Satomi KawamotoJohns Hopkins University, Department of Radiology and Radiology Science, Baltimore, Maryland, United States.ORCID https://orcid.org/0000-0002-3577-1388
J Webster StaymanJohns Hopkins University, Department of Biomedical Engineering, Baltimore, Maryland, United States.ORCID https://orcid.org/0000-0003-4358-378X

Funding

Task-driven dynamic beam modulation for high-performance,low-dose CT.U01EB018758 · NIBIB · JOHNS HOPKINS UNIVERSITY · PI STAYMAN, JOSEPH WEBSTER · 2014 to 2017
$2.6M
NIBIB NIH HHS U01 EB018758
6 · The paper itself

Abstract

Volume-of-interest (VOI) imaging is a strategy in computed tomography (CT) that restricts x-ray fluence to particular anatomical targets via dynamic beam modulation. This permits dose reduction while retaining image quality within the VOI. VOI-CT implementation has been challenged, in part, by a lack of hardware solutions for tailoring the incident fluence to the patient and anatomical site, as well as difficulties involving interior tomography reconstruction of truncated projection data. We propose a general VOI-CT imaging framework using multiple aperture devices (MADs), an emerging beam filtration scheme based on two binary x-ray filters. Location of the VOI is prescribed using two scout views at anterior-posterior (AP) and lateral perspectives. Based on a calibration of achievable fluence field patterns, MAD motion trajectories were designed using an optimization objective that seeks to maximize the relative fluence in the VOI subject to minimum fluence constraints. A modified penalized-likelihood method is developed for reconstruction of heavily truncated data using the full-field scout views to help solve the interior tomography problem. Physical experiments were conducted to show the feasibility of noncentered and elliptical VOI in two applications-spine and lung imaging. Improved dose utilization and retained image quality are validated with respect to standard full-field protocols. We observe that the contrast-to-noise ratio (CNR) is 40% higher compared with low-dose full-field scans at the same dose. The total dose reduction is 50% for equivalent image quality (CNR) within the VOI.

Indexed as

fluence field modulationmodel-based iterative reconstructionvolume-of-interest imaging

Identifiers

PMID31528659
PMCPMC6744926

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.