Evidence map›Paper›PMID 31527486›Full record

ArticleMicromachines2019

An Integrated Portable Multiplex Microchip Device for Fingerprinting Chemical Warfare Agents.

Karolina Petkovic, Anthony Swallow, Robert Stewart, Yuan Gao, Sheng Li, Fiona Glenn, Januar Gotama, Mel Dell'Olio, Michael Best, Justin Doward and 2 more

Open access · goldAbstract read
In one paragraph

Article in Micromachines, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
0.8field-weighted citation impact, top 30% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 14 citations in OpenAlex.

  1. Advances in Portable Heavy Metal Ion Sensors.Sensors (Basel, Switzerland) · 2023
    Review
  2. Article
  3. Review
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

12 authors at 3 institutions in 2 countries.

Karolina PetkovicCSIRO Manufacturing, Bayview Ave, Clayton 3168, Australia.
Anthony SwallowCSIRO Manufacturing, Bayview Ave, Clayton 3168, Australia.
Robert StewartCSIRO Manufacturing, Bayview Ave, Clayton 3168, Australia.
Yuan GaoCSIRO Manufacturing, Bayview Ave, Clayton 3168, Australia.
Sheng LiCSIRO Manufacturing, Bayview Ave, Clayton 3168, Australia.
Fiona GlennCSIRO Manufacturing, Bayview Ave, Clayton 3168, Australia.
Januar GotamaCSIRO Manufacturing, Bayview Ave, Clayton 3168, Australia.
Mel Dell'OlioCSIRO Manufacturing, Bayview Ave, Clayton 3168, Australia.
Michael BestCSIRO Manufacturing, Bayview Ave, Clayton 3168, Australia.
Justin DowardDST, 506 Lorimer Street, Fishermans Bend, VIC 3207, Australia.
Simon OvendonDST, 506 Lorimer Street, Fishermans Bend, VIC 3207, Australia.
Yonggang ZhuCSIRO Manufacturing, Bayview Ave, Clayton 3168, Australia. zhuyonggang@hit.edu.cn.ORCID 0000-0002-5419-9508
CSIRO Manufacturing · AUDefence Science and Technology Group · AUHarbin Institute of Technology · CN

Funding

Department of the Prime Minister and Cabinet PR08-0009
6 · The paper itself

Abstract

The rapid and reliable detection of chemical and biological agents in the field is important for many applications such as national security, environmental monitoring, infectious diseases screening, and so on. Current commercially available devices may suffer from low field deployability, specificity, and reproducibility, as well as a high false alarm rate. This paper reports the development of a portable lab-on-a-chip device that could address these issues. The device integrates a polymer multiplexed microchip system, a contactless conductivity detector, a data acquisition and signal processing system, and a graphic/user interface. The samples are pre-treated by an on-chip capillary electrophoresis system. The separated analytes are detected by conductivity-based microsensors. Extensive studies are carried out to achieve satisfactory reproducibility of the microchip system. Chemical warfare agents soman (GD), sarin (GB), O-ethyl S-[2-diisoproylaminoethyl] methylphsophonothioate (VX), and their degradation products have been tested on the device. It was demonstrated that the device can fingerprint the tested chemical warfare agents. In addition, the detection of ricin and metal ions in water samples was demonstrated. Such a device could be used for the rapid and sensitive on-site detection of both chemical and biological agents in the future.

Indexed as

chemical warfare agentconductivity sensorlab on a chipmicrochip capillary electrophoresis

Identifiers

PMID31527486
PMCPMC6780382
OpenAlexW2974055457

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.