SynthesisPloS one2019
Active transcutaneous bone conduction hearing implants: Systematic review and meta-analysis.
Synthesis in PloS one, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 38 papers, 4 of them syntheses that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
38 citing papers in PubMed, 4 syntheses or guidelines pooled it, 93 citations in OpenAlex.
- Safety profiles of bone-conduction hearing implants revisited: A meta-analytic comparison adjusted for follow-up time.European archives of oto-rhino-laryngology : official journal of the European Federation of Oto-Rhino-Laryngological Societies (EUFOS) : affiliated with the German Society for Oto-Rhino-Laryngology - Head and Neck Surgery · 2025Pooled it
- Systematic Review of Quality of Life in Bone Anchored Hearing: Conductive vs. Unilateral Sensorineural Hearing Loss.The Laryngoscope · 2025Pooled it
- Pooled it
- Ten years of experience with the Ponto bone-anchored hearing system-A systematic literature review.Clinical otolaryngology : official journal of ENT-UK ; official journal of Netherlands Society for Oto-Rhino-Laryngology & Cervico-Facial Surgery · 2020Pooled it
- Nine Years of Experience With Bonebridge: Long-Term Clinical and Audiological Outcomes.Laryngoscope investigative otolaryngology · 2026Article
- Osia Implantation in Patients With Prior Craniotomy for Skull Base Tumors.Otolaryngology--head and neck surgery : official journal of American Academy of Otolaryngology-Head and Neck Surgery · 2026Article
- Linear Versus Curved Incision for Transcutaneous Bone Conduction Implants: Comparative Scar Assessment.International archives of otorhinolaryngology · 2026Article
- Microsurgical Reconstruction of the Ear and Temporal Region: Structural and Functional Considerations Including Hearing Rehabilitation-A Narrative Review.Audiology research · 2026Review
- A Cost-Effectiveness Analysis of the Sentio Bone Conduction Hearing Implant System in the Australian Healthcare Setting.Journal of market access & health policy · 2026Article
- A Prospective, Multicenter Clinical Investigation on the Safety and Performance of a New Active Transcutaneous Bone-Anchored Implant System.Otology & neurotology : official publication of the American Otological Society, American Neurotology Society [and] European Academy of Otology and Neurotology · 2026Article
- Participant valued appearance of bone conduction devices: a comparison between percutaneous and transcutaneous systems.European archives of oto-rhino-laryngology : official journal of the European Federation of Oto-Rhino-Laryngological Societies (EUFOS) : affiliated with the German Society for Oto-Rhino-Laryngology - Head and Neck Surgery · 2025Article
- Improved Speech Recognition in Adults With Conductive or Mixed Hearing Loss Using a Direct-to-Consumer Bone-Conduction Device: A Multiple Methods Intervention Study.JMIR rehabilitation and assistive technologies · 2025Article
- Surgical placement possibilities, audiological benefit, and quality of life following Bonebridge implantation in children.PloS one · 2025Article
- A Non-Surgical Wearable Option for Bone Conduction Hearing Implants: A Comparative Study with Conventional Bone Conduction Hearing Aids Mounted on Eyeglasses.Audiology research · 2024Article
- A MAUDE database analysis on the new generation of active bone conduction hearing implants.Laryngoscope investigative otolaryngology · 2024Article
- Long-Term Patient Satisfaction and Surgical Outcomes With Sophono Implants: A Single-Institution Experience.Cureus · 2024Article
- Comparative Clinical Effectiveness and Cost-Effectiveness of the Cochlear Osia System and Baha Attract System in Patients with Conductive or Mixed Hearing Loss or Single-Sided Deafness.Journal of market access & health policy · 2024Article
- Systematic Review of Current Audiological Treatment Options for Patients with Treacher Collins Syndrome (TCS) and Surgical and Audiological Experiences of an Otorhinolaryngologist with TCS.Journal of personalized medicine · 2024Review
- Evaluating the effectiveness of bone conduction hearing implants in rehabilitation of hearing loss.European archives of oto-rhino-laryngology : official journal of the European Federation of Oto-Rhino-Laryngological Societies (EUFOS) : affiliated with the German Society for Oto-Rhino-Laryngology - Head and Neck Surgery · 2023Article
- Parameters for estimating the feasibility of implantation of a semi-implantable bone conduction device (SIBCD) in children and adolescents.European archives of oto-rhino-laryngology : official journal of the European Federation of Oto-Rhino-Laryngological Societies (EUFOS) : affiliated with the German Society for Oto-Rhino-Laryngology - Head and Neck Surgery · 2023Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors at 1 institution in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundIn July 2018 the active transcutaneous bone conduction hearing implant received FDA approval in the US (for patients 12 years and older with conductive and/or mixed hearing loss or single-sided deafness), reflecting the current trend of moving away from percutaneous hearing solutions towards intact skin systems.
objectivesTo critically assess the current literature on safety, efficacy and subjective benefit after implantation with an active transcutaneous bone conduction hearing device. DATA SOURCES: Literature investigation was performed by electronic database search including PubMed and Cochrane Central Register of Controlled Trials, and manual search of relevant journals and reference lists of included studies. STUDY ELIGIBILITY CRITERIA: Randomized controlled trials, clinical controlled trials and cohort studies, case series and case reports investigating subjective and objective outcomes. STUDY APPRAISAL AND SYNTHESIS
methodsRetrieved literature was screened and extracted by two reviewers independently. Subgroup analysis of indications (conductive and/or mixed hearing loss, single-sided deafness) and participant ages (pediatric vs. adults) was conducted on patients with active transcutaneous bone conduction devices. Sensitivity analysis was performed to test the stability of the results in meta-analysis.
results39 citations reporting on pre- and postoperative audiological results, speech performance in quiet and in noise, localization testing as well as subjective outcomes were included in this systematic review. Functional gain as well as word recognition score outcomes could be further investigated via meta-analysis. All outcomes reported and summarized here reflect beneficial audiological performance and high patient satisfaction, accompanied with a low complications rate (minor event incidence rate: 9.9 person-years; major incidence rate: 148.9 person-years) for the indications of conductive and mixed hearing loss as well as in individuals suffering from single-sided deafness for all age groups of subjects who underwent active transcutaneous bone conduction hearing device implantation. LIMITATIONS: A limiting factor of this systematic review was the Level of Evidence of the reviewed literature, comprising 2a/3a studies (cohort studies and case-control studies). Furthermore, the reporting standards, especially in outcomes such as word recognition scores in quiet and in noise, vary across study cites from various countries, which impedes comparisons. Last but not least, no other comparable other device was retrieved as the active transcutaneous bone conduction hearing device is the only available at the moment.
conclusionThe device's transcutaneous technology results in a minor event incidence rate of one in 9.9 person-years and a major incidence rate of one in 148.9 person-years. Based on the audiological outcomes, high patient satisfaction as well as the low complication rate, the authors recommend the active transcutaneous bone conduction hearing device as a safe and effective treatment for patients suffering from hearing loss within the device's indication criteria (conductive and/or mixed hearing loss or single-sided deafness).
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.