ArticleClinical medicine insights. Arthritis and musculoskeletal disorders2019
Reliability and Accuracy of MRI in Orthopedics: A Survey of Its Use and Perceived Limitations.
Article in Clinical medicine insights. Arthritis and musculoskeletal disorders, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 12 papers, 1 of them a synthesis that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
12 citing papers in PubMed, 1 synthesis or guideline pooled it, 16 citations in OpenAlex.
- Artificial intelligence applied to magnetic resonance imaging reliably detects the presence, but not the location, of meniscus tears: a systematic review and meta-analysis.European radiology · 2024Pooled it
- Zero vs. 30: a diagnostic manual muscle testing technique for detecting full- or partial-thickness supraspinatus muscle tears.JSES reviews, reports, and techniques · 2025Article
- The Use of Magnetic Resonance Imaging in Patients With Shoulder Pain at King Abdulaziz University Hospital.Cureus · 2025Article
- Reliability of glenoid measurements performed using Multiplanar Reconstruction (MPR) of Magnetic Resonance (MRI) in patients with shoulder instability.International orthopaedics · 2024Article
- In-office needle arthroscopy is a cost-effective alternative for operating room diversion in medial meniscectomy: a financial analysis.Journal of orthopaedic surgery and research · 2023Article
- Evaluation of Osteochondral Allograft Transplant Using In-Office Needle Arthroscopy.Arthroscopy techniques · 2022Article
- Utilization of MRI in surgical decision making in the shoulder.BMC musculoskeletal disorders · 2022Article
- Overview of Methods to Quantify Invasiveness of Surgical Approaches in Orthopedic Surgery-A Scoping Review.Frontiers in surgery · 2021Article
- Diagnostic and Therapeutic Elbow Arthroscopy Using Small-Bore Needle Arthroscopy.Arthroscopy techniques · 2020Article
- Diagnostic accuracy of ultrasonography in the assessment of anterior knee pain.Insights into imaging · 2020Article
- Bubble Sign to Confirm the Integrity of the Shoulder Rotator Cuff.Arthroscopy techniques · 2020Article
- Workers' Societal Costs After Knee and Shoulder Injuries and Diagnosis with In-Office Arthroscopy or Delayed MRI: A Cost-Minimization Analysis.JB & JS open accessArticle
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors at 4 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Over the past decade, the use of magnetic resonance imaging (MRI) as a diagnostic tool has been increasing significantly in various fields of medicine due to its wide array of applications. As a result, its diagnostic efficacy and reliability come into question. Specifically, in the field of orthopedics, there has been little discussion on the problems many physicians face while using MRIs in practice. To gauge the perceived limitations of MRI, we designed a decision analysis to analyze the utility of MRIs and estimate the number of inconclusive MRIs ordered within an orthopedic practice to explore potential alternative avenues of diagnosis. A survey of 100 board-certified practicing orthopedic surgeons given at 2 national conferences was designed to assess the value, reliability, and diagnostic utility of MRIs in preoperative planning in shoulder and knee surgery. Of those surveyed, 93% reported that there was believed to be a problem with the accuracy of an MRI in the setting of a prior surgery and/or if previous hardware was present specifically pertaining to the knee or shoulder. The most common indications of concern regarding knee or shoulder MRI reliability among this sample group were previous patient hardware (19%), a previous surgery (16%), and a chondral defect (11%). In addition, when asked how many MRIs were believed to be inconclusive based on previous surgery/hardware alone in the last 6 months of practice, an average of 19 inconclusive MRIs was reported. This study summarizes some of the concerns of MRI use in the orthopedic community and attempts to add a unique perspective on the attitudes, decision-making, and apparent economic problems that they face as well as uncover specific instances where MRIs were determined to be unreliable and incomplete in aiding the diagnosis and treatment algorithm.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.