ArticleEnvironmental pollution (Barking, Essex : 1987)2019
Development of a calibration chamber to evaluate the performance of low-cost particulate matter sensors.
Article in Environmental pollution (Barking, Essex : 1987), 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 17 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
17 citing papers in PubMed.
- Optimization of a Newly Developed Chamber Setup for Spatial Dust Measurements in the Context of Containment.Pharmaceutics · 2025Article
- Pro-inflammatory effects of inhaled Great Salt Lake dust particles.Particle and fibre toxicology · 2025Article
- Pro-Inflammatory Effects of Inhaled Great Salt Lake Dust Particles.Research square · 2024Article
- Investigating the Sensitivity of Low-Cost Sensors in Measuring Particle Number Concentrations across Diverse Atmospheric Conditions in Greece and Spain.Sensors (Basel, Switzerland) · 2023Article
- An analysis of degradation in low-cost particulate matter sensors.Environmental science: atmospheres · 2023Article
- Aerosol Measurement Degradation in Low-Cost Particle Sensors Using Laboratory Calibration and Field Validation.Toxics · 2023Article
- Field Evaluation and Calibration of Low-Cost Air Pollution Sensors for Environmental Exposure Research.Sensors (Basel, Switzerland) · 2022Article
- Establishing A Sustainable Low-Cost Air Quality Monitoring Setup: A Survey of the State-of-the-Art.Sensors (Basel, Switzerland) · 2022Review
- Technical note: Understanding the effect of COVID-19 on particle pollution using a low-cost sensor network.Journal of aerosol science · 2021Article
- On the distribution of low-cost PMJournal of exposure science & environmental epidemiology · 2021Article
- Concurrent assessment of personal, indoor, and outdoor PMIndoor air · 2021Article
- Indoor Air Quality Issues for Rocky Mountain West Tribes.Frontiers in public health · 2021Article
- Investigation on daily exposure to PMJournal of exposure science & environmental epidemiology · 2020Article
- Application of Machine Learning for the in-Field Correction of a PMSensors (Basel, Switzerland) · 2020Article
- Fusion of Environmental Sensing on PMSensors (Basel, Switzerland) · 2020Article
- Laboratory Evaluations of Correction Equations with Multiple Choices for Seed Low-Cost Particle Sensing Devices in Sensor Networks.Sensors (Basel, Switzerland) · 2020Article
- Laboratory Comparison of Low-Cost Particulate Matter Sensors to Measure Transient Events of Pollution.Sensors (Basel, Switzerland) · 2020Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
9 authors.
Funding
Abstract
Low-cost particulate matter (PM) air quality sensors are becoming widely available and are being increasingly deployed in ambient and home/workplace environments due to their low cost, compactness, and ability to provide more highly resolved spatiotemporal PM concentrations. However, the PM data from these sensors are often of questionable quality, and the sensors need to be characterized individually for the environmental conditions under which they will be making measurements. In this study, we designed and assessed a cost-effective (∼$700) calibration chamber capable of continuously providing a uniform PM concentration simultaneously to multiple low-cost PM sensors and robust calibration relationships that are independent of sensor position. The chamber was designed and evaluated with a Computational Fluid Dynamics (CFD) model and a rigorous experimental protocol. We then used this new chamber to calibrate 242 Plantower PMS 3003 sensors from two production lots (Batches I and II) with two aerosol types: ammonium nitrate (for Batches I and II) and alumina oxide (for Batch I). Our CFD models and experiments demonstrated that the chamber is capable of providing uniform PM concentration to 8 PM sensors at once within 6% error and with excellent reliability (intraclass correlation coefficient > 0.771). The study identified two malfunctioning sensors and showed that the remaining sensors had high linear correlations with a DustTrak monitor that was calibrated for each aerosol type (R
Indexed as
Identifiers
What OpenQuestion holds
Registered trials