Evidence map›Paper›PMID 31519192›Full record

ArticleBiomedical engineering online2019

Heart defibrillation: relationship between pacing threshold and defibrillation probability.

Priscila C Antoneli, Jair T Goulart, Isabella Bonilha, Daniela D de Carvalho, Pedro X de Oliveira

Open access · goldAbstract read
In one paragraph

Article in Biomedical engineering online, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
0.5field-weighted citation impact, top 31% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 7 citations in OpenAlex.

  1. [Recent advances in external cardiac defibrillation techniques].Sheng wu yi xue gong cheng xue za zhi = Journal of biomedical engineering = Shengwu yixue gongchengxue zazhi · 2020
    Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 2 institutions in 1 country.

Priscila C AntoneliDepartment of Biomedical Engineering, School of Electrical and Computer Engineering-FEEC, University of Campinas-UNICAMP, Rua Alexander Fleming 163, Cidade Universitária Zeferino Vaz, Campinas, SP, CEP 13083-881, Brazil.
Jair T GoulartDepartment of Physiological Sciences, Institute of Biology, University of Brasilia-UnB, Campus Universitário Darcy Ribeiro-Asa Norte, Brasília, DF, CEP 70910-900, Brazil.
Isabella BonilhaLaboratory of Myocardial Ischemia/Reperfusion, Faculty of Medical Science, University of Campinas-UNICAMP, Rua Cinco de Junho, 350, Bloco 1, Cidade Universitária Zeferino Vaz, Campinas, SP, CEP 13083-877, Brazil.
Daniela D de CarvalhoLaboratory of Myocardial Ischemia/Reperfusion, Faculty of Medical Science, University of Campinas-UNICAMP, Rua Cinco de Junho, 350, Bloco 1, Cidade Universitária Zeferino Vaz, Campinas, SP, CEP 13083-877, Brazil.
Pedro X de OliveiraDepartment of Biomedical Engineering, School of Electrical and Computer Engineering-FEEC, University of Campinas-UNICAMP, Rua Alexander Fleming 163, Cidade Universitária Zeferino Vaz, Campinas, SP, CEP 13083-881, Brazil. pedrox@unicamp.br.ORCID http://orcid.org/0000-0002-1944-7481
Universidade Estadual de Campinas (UNICAMP) · BRUniversidade de Brasília · BR

Funding

FAPESP 2011/51199-6
6 · The paper itself

Abstract

backgroundConsidering the clinical importance of the ventricular fibrillation and that the most used therapy to reverse it has a critical side effect on the cardiac tissue, it is desirable to optimize defibrillation parameters to increase its efficiency. In this study, we investigated the influence of stimuli duration on the relationship between pacing threshold and defibrillation probability.

resultsWe found out that 0.5-ms-long pulses had a lower ratio of defibrillation probability to the pacing threshold, although the higher the pulse duration the lower is the electric field intensity required to defibrillate the hearts.

conclusionThe appropriate choice of defibrillatory shock parameters is able to increase the efficiency of the defibrillation improving the survival chances after the occurrence of a severe arrhythmia. The relationship between pulse duration and the probability of reversal of fibrillation shows that this parameter cannot be underestimated in defibrillator design since different pulse durations have different levels of safety.

Indexed as

AnimalsElectric CountershockHeartMaleMyocytes, CardiacProbabilityRatsRats, WistarSafetyTime FactorsDefibrillationElectric stimulationIsolated rat heart preparationVentricular fibrillation

Identifiers

PMID31519192
PMCPMC6743100
OpenAlexW2972377987

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.