Evidence map›Paper›PMID 31516553›Full record

ArticlePatient safety in surgery2019

Clinical outcomes after carbon-plate osteosynthesis in patients with distal radius fractures.

Florin Allemann, Sascha Halvachizadeh, Thomas Rauer, Hans-Christoph Pape

Open access · goldAbstract read
In one paragraph

Article in Patient safety in surgery, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers, 2 of them syntheses that pooled it.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed, 2 pooled it
1.1field-weighted citation impact, top 22% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed, 2 syntheses or guidelines pooled it, 8 citations in OpenAlex.

  1. Pooled it
  2. Carbon-fibre plates for traumatic and (impending) pathological fracture fixation: Where do we stand? A systematic review.Journal of orthopaedics and traumatology : official journal of the Italian Society of Orthopaedics and Traumatology · 2023
    Pooled it
  3. Fracture fixation in extremity trauma with carbon fiber-reinforced polyetheretherketone (CFR-PEEK) plates: evidence today.European journal of trauma and emergency surgery : official publication of the European Trauma Society · 2022
    Article
  4. Review
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 1 institution in 1 country.

Florin AllemannDepartment of Traumatology, University of Zurich, University Hospital Zurich, Raemistrasse 100, 8091 Zürich, Switzerland.ORCID 0000-0003-0479-2810
Sascha HalvachizadehDepartment of Traumatology, University of Zurich, University Hospital Zurich, Raemistrasse 100, 8091 Zürich, Switzerland.
Thomas RauerDepartment of Traumatology, University of Zurich, University Hospital Zurich, Raemistrasse 100, 8091 Zürich, Switzerland.
Hans-Christoph PapeDepartment of Traumatology, University of Zurich, University Hospital Zurich, Raemistrasse 100, 8091 Zürich, Switzerland.
University of Zurich · CH

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundSurgical implant material has changed over time, from metal to stainless steel to titanium. In recent decades a new material, carbon-fibre-reinforced polyether ether ketone, has been introduced. The aim of this study was to assess the clinical and radiological feasibility and functional outcome after treatment of distal radius fractures with this new implant.

methodsInclusion criteria: AO type B distal radius fractures treated with 2.7 mm CF/PEEK plates at one Level 1 trauma centre between 2016 and 2017. Follow-up period 1 year, measurement of range of motion and radiographic assessment, histological analysis of debris only after plate removal.

resultsOut of 112 eligible patients, 10 (8.9%) patients were included. Mean operation time was 65 ± 10 min. Radiographic healing was confirmed by radiologists at 6 weeks follow-up. During one-year follow-up, no adverse events were reported and functionality and patients subjective satisfaction improved significantly (

conclusionsThe 2.7 mm CF/PEEK plate osteosynthesis appears to be a reliable and safe implant for certain types of distal radius fracture. Assessment of fracture union is substantially more practical and functionality improved significantly over 1 year.

Indexed as

Carbon implantCF/PEEK platesDistal radius fracturePlate osteosynthesisWrist fracture

Identifiers

PMID31516553
PMCPMC6727488
OpenAlexW2972287355

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.