Evidence map›Paper›PMID 31515214›Full record

ArticleAJNR. American journal of neuroradiology2019

PACS Integration of Semiautomated Imaging Software Improves Day-to-Day MS Disease Activity Detection.

A Dahan, R Pereira, C B Malpas, T Kalincik, F Gaillard

Abstract read
In one paragraph

Article in AJNR. American journal of neuroradiology, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed.

  1. Deep Learning Framework for Automated MRI Planimetry in Multiple Sclerosis.International journal of biomedical imaging · 2026
    Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

A DahanFrom the Department of Radiology (A.D.), Austin Hospital, Heidelberg, Australia ariel.dahan@austin.org.au.ORCID 0000-0003-3205-425X
R PereiraDepartments of Radiology (R.P., F.G.).ORCID 0000-0002-7965-2065
C B MalpasNeurology (T.K., C.M.), Royal Melbourne Hospital, Parkville, Victoria, Australia.ORCID 0000-0003-0534-3718
T KalincikNeurology (T.K., C.M.), Royal Melbourne Hospital, Parkville, Victoria, Australia.ORCID 0000-0003-3778-1376
F GaillardDepartments of Radiology (R.P., F.G.).ORCID 0000-0002-2382-872X

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

background and purposeThe standard for evaluating interval radiologic activity in MS, side-by-side MR imaging comparison, is restricted by its time-consuming nature and limited sensitivity. VisTarsier, a semiautomated software for comparing volumetric FLAIR sequences, has shown better disease-activity detection than conventional comparison in retrospective studies. Our objective was to determine whether implementing this software in day-to-day practice would show similar efficacy. MATERIALS AND

methodsVisTarsier created an additional coregistered image series for reporting a color-coded disease-activity change map for every new MS MR imaging brain study that contained volumetric FLAIR sequences. All other MS studies, including those generated during software-maintenance periods, were interpreted with side-by-side comparison only. The number of new lesions reported with software assistance was compared with those observed with traditional assessment in a generalized linear mixed model. Questionnaires were sent to participating radiologists to evaluate the perceived day-to-day impact of the software.

resultsNine hundred six study pairs from 538 patients during 2 years were included. The semiautomated software was used in 841 study pairs, while the remaining 65 used conventional comparison only. Twenty percent of software-aided studies reported having new lesions versus 9% with standard comparison only. The use of this software was associated with an odds ratio of 4.15 for detection of new or enlarging lesions (

conclusionsVisTarsier can be implemented in real-world clinical settings with good acceptance and preservation of accuracy demonstrated in a retrospective environment.

Indexed as

SoftwareAdultAutomationDisease ProgressionFemaleHumansImage Processing, Computer-AssistedLinear ModelsMagnetic Resonance ImagingMaleMiddle AgedMultiple SclerosisNeuroimagingReproducibility of ResultsRetrospective StudiesSurveys and Questionnaires

Identifiers

PMID31515214
PMCPMC7028546

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked