Robust HU-based CT ventilation from an integrated mass conservation formulation.

Edward Castillo, Yevgeniy Vinogradskiy, Richard Castillo

Abstract read
In one paragraph

Article in Medical physics, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 13 papers.

0numbers the graph read from it
0cells of the map it votes in
13citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

13 citing papers in PubMed.

  1. Trial
  2. Trial
  3. Article
  4. Article
  5. Article
  6. [Research progress on predicting radiation pneumonia based on four-dimensional computed tomography ventilation imaging in lung cancer radiotherapy].Sheng wu yi xue gong cheng xue za zhi = Journal of biomedical engineering = Shengwu yixue gongchengxue zazhi · 2025
    Review
  7. Article
  8. Article
  9. Article
  10. Article
  11. Article
  12. Article
  13. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

Edward CastilloDepartment of Radiation Oncology, Beaumont Health Systems, Royal Oak, MI, USA.
Yevgeniy VinogradskiyDepartment of Radiation Oncology, University of Colorado, Denver, CO, USA.
Richard CastilloDepartment of Radiation Oncology, Emory University, Atlanta, GA, USA.

Funding

Clinical trial personalizing radiation therapy through a novel lung function imaging modalityR01CA200817 · NCI · UNIVERSITY OF COLORADO DENVER · PI VINOGRADSKIY, YEVGENIY · 2016 to 2018
$618k
NCI NIH HHS R01 CA200817NIH HHS R01CA200817University of Michigan
6 · The paper itself

Abstract

Computed tomography (CT) ventilation algorithms estimate volume changes induced by respiratory motion. Existing Hounsfield Unit (HU) methods approximate volume change from the measured HU variations between spatially corresponding voxel locations within a temporally resolved CT image pair, assuming that volume changes are caused solely by changes in air content. Numerical implementations require a deformable image registration to determine the inhale/exhale spatial correspondence, a preprocessing lung volume segmentation, a preprocessing high-intensity vessel segmentation, and a post-processing smoothing applied to the raw volume change estimates obtained for each lung tissue voxel. PURPOSE: We introduce the novel mass-conserving volume change (MCVC) method for estimating voxel volume changes from the HU values within an inhale/exhale CT image pair. MCVC is based on subregional volume change estimates that possess quantitatively characterized and controllable levels of uncertainty. MCVC is therefore robust to small variations in DIR solutions and the resulting ventilation images are overall more reproducible. In contrast to existing HU methods, MCVC does not require a preprocessing lung vessel segmentation or pre/post-processing Gaussian smoothing.

methodsSubregional volume change estimates are defined in terms of mean density ratios. As such, the corresponding uncertainty is characterized using Gaussian statistics and standard error analysis of the sample density means. A numerical solution is obtained from the MCVC formulation by solving a constrained linear least squares problem defined by a series of subregional volume change estimates. Reproducibility of the MCVC method with respect to DIR solution was assessed using expert-determined landmark point pairs and inhale/exhale phases from 10 four-dimensional CTs (4DCTs) available on www.dir-lab.com. MCVC was also compared to the robust Integrated Jacobian Formulation (IJF), a transformation-based ventilation method.

resultsThe ten Dir-Lab 4DCT cases were registered twice with the same DIR algorithm, but using different degrees of freedom (DIR 1 and DIR 2). Standard HU ventilation (HUV) and MCVC ventilation images were computed for both solutions. The average spatial errors (300 landmarks per case) for DIR 1 ranged between 0.74 and 1.50 mm, whereas for DIR 2 they ranged between 0.68 and 1.18 mm. Despite the differences in spatial errors between the two DIR solutions, the average Pearson correlation between the corresponding HUV images was 0.94 (0.03), while for the MCVC images it was 1.00 (0.00). The average correlation between MCVC and IJF ventilation over the ten test cases was 0.81 (0.14), whereas for HUV and IJF it was 0.56 (1.11).

conclusionWhile HUV is robust to DIR solution, its implementation depends on heuristic Gaussian smoothing and vessel segmentation. MCVC is based on subregional volume change measurements with quantifiable and controllable levels of uncertainty. The subregional approach eliminates the need for Gaussian smoothing and lung vasculature segmentation. Numerical experiments are consistent with the underlying mathematical theory and indicate that MCVC ventilation is more reproducible with respect to DIR algorithm than standard HU methods. MCVC results are also more consistent with the robust IJF method, which suggests that incorporating robustness leads to more consistent results across both DIRs and ventilation algorithms.

Indexed as

Four-Dimensional Computed TomographyPulmonary VentilationAlgorithmsHumansImage Processing, Computer-AssistedNormal DistributionRespiration4DCTcomputed tomographydeformable image registrationventilation

Identifiers

PMID31514235
PMCPMC6842051

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.