Evidence map›Paper›PMID 31511942›Full record

ArticleWorld journal of surgery2020

Use of Electrical Impedance Spectroscopy for Intraoperative Tissue Differentiation During Thyroid and Parathyroid Surgery.

Sarah L Hillary, Brian H Brown, Nicola J Brown, Saba P Balasubramanian

Registry-linked trialAbstract readClinical Trial, Phase I
PubMed Publisher
In one paragraph

Article in World journal of surgery, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to trial NCT02901873 (Phase 1 Study of Electrical Impedance Spectroscopy in Thyroid and Parathyroid Surgery), which is not on this map. Cited by 9 papers.

0numbers the graph read from it
0cells of the map it votes in
9citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

NCT02901873 nacompletednot on this map

Phase 1 Study of Electrical Impedance Spectroscopy in Thyroid and Parathyroid Surgery

TypeinterventionalSponsorSheffield Teaching Hospitals NHS Foundation TrustRan2016 to 2017Enrolled56ConditionsThyroidectomy, Parathyroid DiseasesArmsElectrical Impedance Spectroscopy
3 · Its place in the literature

Who cites it

9 citing papers in PubMed.

  1. Article
  2. Review
  3. Article
  4. Article
  5. Article
  6. Multiscale Model Development for Electrical Properties of Thyroid and Parathyroid Tissues.IEEE open journal of engineering in medicine and biology · 2024
    Article
  7. Article
  8. Article
  9. Article
4 · The record

Corrections and comments

5 · Who and what money

Authors and funding

4 authors.

Sarah L HillaryUniversity of Sheffield, Sheffield, UK. sarah.hillary@doctors.org.uk.ORCID http://orcid.org/0000-0002-6938-6920
Brian H BrownUniversity of Sheffield, Sheffield, UK.
Nicola J BrownUniversity of Sheffield, Sheffield, UK.
Saba P BalasubramanianSheffield Teaching Hospitals NHS Foundation Trust, University of Sheffield, Sheffield, UK.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundElectrical impedance (EI) measures tissue resistance to alternating current across several frequencies and may help identify tissue type. A recent rabbit model demonstrated that electrical impedance spectroscopy (EIS) may facilitate identification of parathyroid glands and potentially improve outcomes following surgery. This study looks at the EI patterns of soft tissues in the human neck to determine whether parathyroid tissue can be accurately identified.

methodsThis was a phase 1, single-arm interventional study involving 56 patients undergoing thyroid and/or parathyroid surgery. Up to 12 EI readings were taken from in vivo and ex vivo thyroid and parathyroid glands, adipose tissue and muscle of each patient. Each reading consists of a series of measurements over 14 frequencies from each tissue. EI patterns were analysed. Two patients were excluded due to data loss due to device malfunction.

resultsThe median age of participants was 53.5 (range 20-85) years. Thirty-five participants had surgery for thyroid pathology, 17 for parathyroid pathology and four for both. Six hundred and six EIS spectra were reviewed for suitability. One hundred and eighty-four spectra were rejected leaving 422 spectra for analysis. The impedance patterns of the soft tissues differed by histological type. The EI ratio of low (152 Hz) to high (312 kHz) frequencies demonstrated a significant difference between the soft tissues (p = 0.006). Using appropriate thresholds, parathyroid tissue can be distinguished from thyroid tissue with a sensitivity of 76% and specificity of 60%.

conclusionsThis study demonstrates the feasibility of using EIS to aid parathyroid identification and preservation. Further changes to the device and modelling of the EI patterns across the range of frequencies may improve accuracy and facilitate intraoperative use.

trial registrationClinicalTrials.gov (NCT02901873).

Indexed as

AdultAgedAged, 80 and overDielectric SpectroscopyFemaleHumansMaleMiddle AgedParathyroid GlandsProspective StudiesThyroid GlandYoung Adult

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.