Evidence map›Paper›PMID 31511816›Full record

ArticleCureus2019

Evaluation of Titanium Serum Levels in Patients After Spine Instrumentation: Comparison Between Posterolateral and 360º Spinal Fusion Surgery.

Ignacio Fernández Bances, José Paz Aparicio, Marco Antonio Alvarez Vega

Open access · diamondAbstract read
In one paragraph

Article in Cureus, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed, 1 pooled it
0.9field-weighted citation impact, top 25% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed, 1 synthesis or guideline pooled it, 10 citations in OpenAlex.

  1. Pooled it
  2. Review
  3. Review
  4. Review
  5. Article
  6. Article
  7. The Mechanism of Metallosis After Total Hip Arthroplasty.Regenerative engineering and translational medicine · 2021
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors at 1 institution in 1 country.

Ignacio Fernández BancesSpine Unit, Orthopedic Department, Complejo Asistencial Universitario De León, León, ESP.
José Paz AparicioSpine Unit, Orthopedic Surgery and Traumatology Department, University Central Hospital of Asturias, Oviedo, ESP.
Marco Antonio Alvarez VegaNeurosurgery Department, University Central Hospital of Asturias-Huca, Oviedo, ESP.
Complejo Asistencial Universitario de Palencia · ES

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Introduction The use of orthopedic implants is a cause for concern for the release of its integrating metals and the systemic complications that may occur. Instrumented spine arthrodesis is the recommended treatment for many spine diseases. Different segmental fixation devices, commonly made of titanium and its alloys, are used in these surgeries. The use of this metal for spinal fusion has introduced the possibility of generating microscopic metal particles that are present in the tissues of the surrounding implants (peri-implant environment). In fact, metal debris has been found in the paraspinal soft tissues of patients with posterior lumbar instrumentation and showed to be particularly high in patients undergoing revision procedures of pseudoarthrosis. In addition, part of the metals might also dissolve (either from the released particles or directly from the implant surface) and circulate in the body fluids, accumulating (eventually) in remote organs. Material and methods A prospective study was designed with patients who were to be operated by the pathology of the lumbar spine to perform a vertebral arthrodesis composed of a titanium alloy (n=32). Two subgroups were differentiated according to the type of surgery performed: a) Posterolateral arthrodesis (N=5); b) Circumferential arthrodesis intervertebral implant of polyester-ether ketone (PEEK) (N=8) or titanium (N=19). The blood sample was taken before surgery and one year later. The samples were analyzed by mass spectrophotometry with a double focus inductive coupling plasma source (DF-ICP-MS). Results Blood titanium levels prior to surgery were similar to those in other publications (0.7449 micrograms per liter

Indexed as

interbody devicesisotope dilution analysismetal ion releaseserum titanium levelsspine fusion

Identifiers

PMID31511816
PMCPMC6716769
OpenAlexW2969293374

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.