Evidence map›Paper›PMID 31509987›Full record

ArticleSensors (Basel, Switzerland)2019

Flex Sensor Compensator via Hammerstein-Wiener Modeling Approach for Improved Dynamic Goniometry and Constrained Control of a Bionic Hand.

Syed Afdar Ali Syed Mubarak Ali, Nur Syazreen Ahmad, Patrick Goh

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

Syed Afdar Ali Syed Mubarak AliSchool of Electrical and Electronic Engineering, Engineering Campus, Universiti Sains Malaysia, 14300 Nibong Tebal, Pulau Pinang, Malaysia.
Nur Syazreen AhmadSchool of Electrical and Electronic Engineering, Engineering Campus, Universiti Sains Malaysia, 14300 Nibong Tebal, Pulau Pinang, Malaysia. syazreen@usm.my.ORCID 0000-0003-2615-8386
Patrick GohSchool of Electrical and Electronic Engineering, Engineering Campus, Universiti Sains Malaysia, 14300 Nibong Tebal, Pulau Pinang, Malaysia.

Funding

Universiti Sains Malaysia 1001/PELECT/8014055
6 · The paper itself

Abstract

In this paper, a new control-centric approach is introduced to model the characteristics of flex sensors on a goniometric glove, which is designed to capture the user hand gesture that can be used to wirelessly control a bionic hand. The main technique employs the inverse dynamic model strategy along with a black-box identification for the compensator design, which is aimed to provide an approximate linear mapping between the raw sensor output and the dynamic finger goniometry. To smoothly recover the goniometry on the bionic hand's side during the wireless transmission, the compensator is restructured into a Hammerstein-Wiener model, which consists of a linear dynamic system and two static nonlinearities. A series of real-time experiments involving several hand gestures have been conducted to analyze the performance of the proposed method. The associated temporal and spatial gesture data from both the glove and the bionic hand are recorded, and the performance is evaluated in terms of the integral of absolute error between the glove's and the bionic hand's dynamic goniometry. The proposed method is also compared with the raw sensor data, which has been preliminarily calibrated with the finger goniometry, and the Wiener model, which is based on the initial inverse dynamic design strategy. Experimental results with several trials for each gesture show that a great improvement is obtained via the Hammerstein-Wiener compensator approach where the resulting average errors are significantly smaller than the other two methods. This concludes that the proposed strategy can remarkably improve the dynamic goniometry of the glove, and thus provides a smooth human-robot collaboration with the bionic hand.

Indexed as

AlgorithmsArthrometry, ArticularBionicsBiomechanical PhenomenaHandHumansflex sensorHammerstein–Wienerhand gesture

Identifiers

PMID31509987
PMCPMC6767013

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.