ArticlePhysics in medicine and biology2019
Task-driven optimization of the non-spectral mode of photon counting CT for intracranial hemorrhage assessment.
Article in Physics in medicine and biology, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 9 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
9 citing papers in PubMed, 20 citations in OpenAlex.
- Gaussian Function Model for Task-Specific Evaluation in Medical Imaging: A Theoretical Investigation.Journal of imaging informatics in medicine · 2026Article
- Quantifying photon counting detector (PCD) performance using PCD-CT images.Medical physics · 2025Article
- Correcting statistical CT number biases without access to raw detector counts: Applications to high spatial resolution photon counting CT imaging.Medical physics · 2023Article
- Simultaneous photon counting and charge integrating for pulse pile-up correction in paralyzable photon counting detectors.Physics in medicine and biology · 2023Article
- Photon counting-energy integrating hybrid flat panel detector systems for image-guided interventions: an experimental proof-of-concept.Physics in medicine and biology · 2023Article
- A C-arm photon counting CT prototype with volumetric coverage using multi-sweep step-and-shoot acquisitions.Physics in medicine and biology · 2022Article
- Spectral Photon Counting CT: Imaging Algorithms and Performance Assessment.IEEE transactions on radiation and plasma medical sciences · 2021Article
- Photon Counting CT: Clinical Applications and Future Developments.IEEE transactions on radiation and plasma medical sciences · 2021Article
- Anomalous edge response of cadmium telluride-based photon counting detectors jointly caused by high-flux radiation and inter-pixel communication.Physics in medicine and biology · 2021Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors at 1 institution in 1 country.
Funding
Abstract
Non-contrast CT (NCCT) is widely employed as the first-line imaging test to evaluate intracranial hemorrhage (ICH). Advances in mutidetector CT (MDCT) technology have greatly improved the image quality of NCCT for the detection of established, relatively large, and acute ICHs. Meanwhile, the reliability of MDCT in detecting microbleeds and chronic hemorrhage, and in predicting hemorrhagic transformation needs to be further improved. The purpose of this work was to investigate the potential use of non-spectral photon counting CT (PCCT) to address these challenges in ICH imaging. Towards this goal, the NCCT protocol of an experimental PCCT system that simulates the geometry of a general-purpose MDCT was optimized. The optimization was driven by three imaging tasks: detection of a 4.0 mm intraparenchymal hemorrhage, detection of a 1.5 mm subarachnoid hemorrhage, and discrimination of a sulcus in the insular cortex from the parenchymal background. These imaging tasks were custom-built into an anthropomorphic head phantom. Under the guidance of the frequency-dependent noise equivalent quanta and the ideal observer model detectability index [Formula: see text], the optimal PCD detection mode, energy threshold, and reconstruction kernel were found to be the anti-charge sharing mode, 15 keV, and an apodized ramp kernel, respectively. Compared with a clinical MDCT operated with an ICH protocol and at a matched dose level, the PCCT system provided at least 20% improvements in [Formula: see text] for all three ICH imaging tasks. These results demonstrated the potential benefits of non-spectral PCCT in ICH assessment.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials