Evidence map›Paper›PMID 31506872›Full record

ArticleJournal of interventional cardiac electrophysiology : an international journal of arrhythmias and pacing2019

ICD shocks in LVAD patients are not associated with increased subsequent mortality risk.

Aswini Kumar, Varun Tandon, David M O'Sullivan, Edmond Cronin, Jason Gluck, Jeffrey Kluger

Abstract read
PubMed Publisher
In one paragraph

Article in Journal of interventional cardiac electrophysiology : an international journal of arrhythmias and pacing, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed, 1 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed, 1 synthesis or guideline pooled it.

  1. Pooled it
  2. Observational
  3. Article
  4. Article
  5. Review
  6. Article
  7. Electromagnetic interference between implantable cardiac devices and continuous-flow left ventricular assist devices: a review.Journal of interventional cardiac electrophysiology : an international journal of arrhythmias and pacing · 2021
    Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Aswini KumarDivision of Cardiology, Hartford Hospital, Hartford, CT, USA. Drop2ash@gmail.com.ORCID http://orcid.org/0000-0001-5946-7498
Varun TandonDepartment of Medicine, University of Connecticut, Farmington, CT, USA.
David M O'SullivanDepartment of Research Administration, Hartford HealthCare, Hartford, CT, USA.
Edmond CroninDivision of Cardiology, Hartford Hospital, Hartford, CT, USA.
Jason GluckDivision of Cardiology, Hartford Hospital, Hartford, CT, USA.
Jeffrey KlugerDivision of Cardiology, Hartford Hospital, Hartford, CT, USA.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundImplantable cardioverter-defibrillator (ICD) shocks are associated with increased mortality risk in heart failure patients. Whether ICD shocks are associated with mortality in continuous flow LVAD (CF-LVAD) patients is unknown. We studied the relationship of ICD shocks and ventricular arrhythmias (VAs) to morbidity and mortality in CF-LVAD-supported patients in our institution.

methodsSingle-center, retrospective study of prospectively collected ICD and LVAD databases. We analyzed data on VA which received ICD therapy in patients who underwent CF-LVAD implantation at Hartford Hospital between 2008 and 2018.

resultsA total of 157 patients were studied. During a median follow-up of 10 months (interquartile range 5-20 months), 48 patients (30.6%) experienced post-LVAD sustained VA. Thirty patients (19.1%) had appropriate shocks for VA and 5 patients (3.1%) had inappropriate shocks. Shocks for any arrhythmia were not associated with an increased risk of death (OR 0.836, 95% CI 0.224-3.115, p = 0.789). Neither post-LVAD VA nor the rate of VA was associated with an increased mortality risk (OR 0.662 [0.329-1.334], p = 0.248; OR 1.001 [0.989-1.014], p = 0.817, respectively). Cox multivariate regression analysis revealed pre-LVAD VA as a significant predictor of VA post LVAD implantation (OR 3.284 [1.584-6.808], p = 0.001). Symptoms with VA occurred in 22 (45.8%) patients, ranging from palpitations to near syncope/syncope. None of the variables including the rate of VA was associated with death or symptoms.

conclusionsVAs are common in CF-LVAD patients and occur with higher frequency in those with pre-LVAD VA and frequently cause symptoms. Neither VA nor ICD shocks are associated with mortality risk.

Indexed as

Defibrillators, ImplantableAgedFemaleHeart FailureHumansMaleMiddle AgedRetrospective StudiesRisk FactorsTachycardia, VentricularICD shocksLVADMortalitySymptomsVentricular arrhythmia

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.