ArticleJournal of radiation research2019
Assessment of abdominal organ motion using cine magnetic resonance imaging in different gastric motilities: a comparison between fasting and postprandial states.
Article in Journal of radiation research, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 14 papers, 1 of them a synthesis that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
14 citing papers in PubMed, 1 synthesis or guideline pooled it, 19 citations in OpenAlex.
- Economic Evaluations of Magnetic Resonance Image-Guided Radiotherapy (MRIgRT): A Systematic Review.International journal of environmental research and public health · 2022Pooled it
- Motion Mitigation Techniques for Abdominal and Cardiac MR Imaging.Journal of magnetic resonance imaging : JMRI · 2026Review
- Diagnosis of Functional Dyspepsia and Novel Gastrointestinal Functional Assessments.Digestion · 2026Review
- Evaluation of a fast-volumetric four-dimensional magnetic resonance imaging technique for abdominal radiotherapy tumor motion management.Quantitative imaging in medicine and surgery · 2025Article
- Evaluation of Gastric Peristalsis Using Cine MRI in Healthy Subjects and Patients With Functional Dyspepsia.Clinical and translational gastroenterology · 2025Article
- A vessel bifurcation landmark pair dataset for abdominal CT deformable image registration (DIR) validation.Medical physics · 2025Article
- Multi-parametric MRI for radiotherapy simulation.Medical physics · 2023Review
- Image guidance and interfractional anatomical variation in paediatric abdominal radiotherapy.The British journal of radiology · 2023Article
- Development of an abdominal dose accumulation tool and assessments of accumulated dose in gastrointestinal organs.Physics in medicine and biology · 2023Article
- MRI-LINAC: A transformative technology in radiation oncology.Frontiers in oncology · 2023Review
- Magnetic resonance linear accelerator technology and adaptive radiation therapy: An overview for clinicians.CA: a cancer journal for clinicians · 2022Review
- Modeling intra-fractional abdominal configuration changes using breathing motion-corrected radial MRI.Physics in medicine and biology · 2021Article
- A hierarchical model of abdominal configuration changes extracted from golden angle radial magnetic resonance imaging.Physics in medicine and biology · 2021Article
- Dosimetric predictors of nephrotoxicity in patients receiving extended-field radiation therapy for gynecologic cancer.Radiation oncology (London, England) · 2021Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors at 1 institution in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
This study assessed abdominal organ motion induced by gastroduodenal motilities in volunteers during fasting and postprandial states, using cine magnetic resonance imaging (cine-MRI). Thirty-five volunteers underwent cine-MRI while holding their breath in the fasting and postprandial states. Gastric motility was quantified by the amplitude and velocity of antral peristaltic waves. Duodenal motility was evaluated as the change of duodenal diameter. Abdominal organ motion was measured in the liver, pancreas and kidneys. Motion was quantified by calculating maximal organ displacement in the left-right, antero-posterior and caudal-cranial directions. Median antral amplitude and velocity in the fasting and postprandial states were 7.7 and 15.1 mm (P < 0.01), and 1.3 and 2.5 mm/s (P < 0.01), respectively. Duodenal motility did not change. Median displacement for all organs ranged from 0.9 to 2.9 mm in the fasting state and from 1.0 to 2.9 mm in the postprandial state. Significant increases in abdominal organ displacement in the postprandial state were observed in the right lobe of the liver, pancreatic head and both kidneys. Differences in the median displacement of these organs between the two states were all <1 mm. Although the motion of several abdominal organs increased in the postprandial state, the difference between the two states was quite small. Thus, our study suggests that treatment planning and irradiation need not include strict management of gastric conditions, nor the addition of excess margins to compensate for differences in the intra-fractional abdominal organ motion under different gastric motilities in the fasting and postprandial states.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.