ArticleInvestigative radiology2020
Development of Upright Computed Tomography With Area Detector for Whole-Body Scans: Phantom Study, Efficacy on Workflow, Effect of Gravity on Human Body, and Potential Clinical Impact.
Article in Investigative radiology, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 68 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
68 citing papers in PubMed, 122 citations in OpenAlex.
- Thoracic posture-related morphological changes in patients with pectus excavatum versus healthy controls.European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery · 2024Trial
- Comparison of Lung, Lobe, and Airway Volumes between Supine and Upright Computed Tomography and Their Correlation with Pulmonary Function Test in Patients with Chronic Obstructive Pulmonary Disease.Respiration; international review of thoracic diseases · 2022Trial
- Upright MDCT evaluation of gravity-induced bronchial collapse and paradoxical lung volume reduction in severe thoracic lordoscoliosis: A case report.Radiology case reports · 2026Article
- Metabolic syndrome: comparison of diagnostic capability among waist circumference and supine and upright multidetector computed tomography.Japanese journal of radiology · 2026Article
- Application of upright multidetector CT in orthopedics and the musculoskeletal system: insights into anatomy, alignment, and biomechanics.Japanese journal of radiology · 2026Review
- Longitudinal CT number characterization of a novel upright CT for proton therapy planning.Journal of applied clinical medical physics · 2026Article
- Feasibility of upright carbon ion radiotherapy for prostate cancer: Dosimetric comparison between supine and upright postures.Medical physics · 2026Article
- Effect of body position on cerebral perfusion: a comparison of supine and seated positions assessed using conventional and upright CT perfusion.European radiology experimental · 2026Observational
- Comparison of biomechanical assessment between upright and supine inspiratory-expiratory area-detector CT in progressive pulmonary fibrosis.European radiology experimental · 2026Article
- Article
- Weight-bearing computed tomography in knee pathologies: current evidence and future perspectives.Frontiers in surgery · 2026Review
- Evaluating the compatibility of the 2D and 3D facial soft tissue depth measurement methods.International journal of legal medicine · 2026Article
- Multimodal deep learning ensemble framework for skin cancer detection.Scientific reports · 2025Article
- Effect of posture on renal volume: evaluation using multi-posture MRI.Radiological physics and technology · 2025Article
- Detection of Age-Related Pelvic Floor Fragility in Female Patients Using Magnetic Resonance Imaging.International urogynecology journal · 2025Article
- [Computed tomography of the chest in children : Indications, technical optimization, and future perspectives].Radiologie (Heidelberg, Germany) · 2025Review
- Upright multidetector CT with 320-row gantry: a technical innovation providing insights into human anatomy under gravity and potential clinical implications.The British journal of radiology · 2025Article
- Subtalar joint kinematics defined by a rotational axis translating along the posterior talocalcaneal facet.Scientific reports · 2025Article
- Equivalence assessment of weight bearing cone beam CT and multidetector CT through 3D Knee bone modelling.Scientific reports · 2025Article
- Comparative analysis of residual setup errors in head and neck patients from upright versus supine radiotherapy postures.Medical physics · 2025Article
8 more citing papers are in PubMed but not listed here.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
8 authors at 2 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
objectivesMultiple human systems are greatly affected by gravity, and many disease symptoms are altered by posture. However, the overall anatomical structure and pathophysiology of the human body while standing has not been thoroughly analyzed due to the limitations of various upright imaging modalities, such as low spatial resolution, low contrast resolution, limited scan range, or long examination time. Recently, we developed an upright computed tomography (CT), which enables whole-torso cross-sectional scanning with 3-dimensional acquisition within 15 seconds. The purpose of this study was to evaluate the performance, workflow efficacy, effects of gravity on a large circulation system and the pelvic floor, and potential clinical impact of upright CT. MATERIALS AND
methodsWe compared noise characteristics, spatial resolution, and CT numbers in a phantom between supine and upright CT. Thirty-two asymptomatic volunteers (48.4 ± 11.5 years) prospectively underwent both CT examinations with the same scanning protocols on the same day. We conducted a questionnaire survey among these volunteers who underwent the upright CT examination to determine their opinions regarding the stability of using the pole throughout the acquisition (closed question), as well as safety and comfortability throughout each examination (both used 5-point scales). The total access time (sum of entry time and exit time) and gravity effects on a large circulation system and the pelvic floor were evaluated using the Wilcoxon signed-rank test and the Mann-Whitney U test. For a large circulation system, the areas of the vena cava and aorta were evaluated at 3 points (superior vena cava or ascending aorta, at the level of the diaphragm, and inferior vena cava or abdominal aorta). For the pelvic floor, distances were evaluated from the bladder neck to the pubococcygeal line and the anorectal junction to the pubococcygeal line. We also examined the usefulness of the upright CT in patients with functional diseases of spondylolisthesis, pelvic floor prolapse, and inguinal hernia.
resultsNoise characteristics, spatial resolution, and CT numbers on upright CT were comparable to those of supine CT. In the volunteer study, all volunteers answered yes regarding the stability of using the pole, and most reported feeling safe (average rating of 4.2) and comfortable (average rating of 3.8) throughout the upright CT examination. The total access time for the upright CT was significantly reduced by 56% in comparison with that of supine CT (upright: 41 ± 9 seconds vs supine: 91 ± 15 seconds, P < 0.001). In the upright position, the area of superior vena cava was 80% smaller than that of the supine position (upright: 39.9 ± 17.4 mm vs supine: 195.4 ± 52.2 mm, P < 0.001), the area at the level of the diaphragm was similar (upright: 428.3 ± 87.9 mm vs supine: 426.1 ± 82.0 mm, P = 0.866), and the area of inferior vena cava was 37% larger (upright: 346.6 ± 96.9 mm vs supine: 252.5 ± 93.1 mm, P < 0.001), whereas the areas of aortas did not significantly differ among the 3 levels. The bladder neck and anorectal junction significantly descended (9.4 ± 6.0 mm and 8.0 ± 5.6 mm, respectively, both P < 0.001) in the standing position, relative to their levels in the supine position. This tendency of the bladder neck to descend was more prominent in women than in men (12.2 ± 5.2 mm in women vs 6.7 ± 5.6 mm in men, P = 0.006). In 3 patients, upright CT revealed lumbar foraminal stenosis, bladder prolapse, and inguinal hernia; moreover, it clarified the grade or clinical significance of the disease in a manner that was not apparent on conventional CT.
conclusionsUpright CT was comparable to supine CT in physical characteristics, and it significantly reduced the access time for examination. Upright CT was useful in clarifying the effect of gravity on the human body: gravity differentially affected the volume and shape of the vena cava, depending on body position. The pelvic floor descended significantly in the standing position, compared with its location in the supine position, and the descent of the bladder neck was more prominent in women than in men. Upright CT could potentially aid in objective diagnosis and determination of the grade or clinical significance of common functional diseases.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.