ArticleSkeletal radiology2020
Ultra-low-dose CT for extremities in an acute setting: initial experience with 203 subjects.
Article in Skeletal radiology, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 15 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
15 citing papers in PubMed.
- The clinical performance of ultra-low-dose shoulder CT scans: The assessment on image and physical 3D printing models.PloS one · 2022Trial
- Image quality and radiation dose of cone-beam CT versus multidetector CT for upper extremity osteosynthesis.Scientific reports · 2026Article
- Dose-reduction strategies in whole-body CT for injured patients in the emergency department: a scoping review.International journal of emergency medicine · 2026Review
- Current and future role of CT and advanced CT applications in inflammatory arthritis in the clinic and trials.Skeletal radiology · 2025Review
- Ultra-Low Dose Computed Tomography Imaging in Quantifying Bone Trauma and Disorders: A Cross-Sectional Study.Iranian journal of medical sciences · 2025Article
- Diagnostic Accuracy of Ultra-Low Dose CT Compared to Standard Dose CT for Identification of Fresh Rib Fractures by Deep Learning Algorithm.Journal of imaging informatics in medicine · 2025Article
- Diagnostic accuracy of ultra-low-dose CT compared to standard-dose CT for identification of non-displaced fractures of the shoulder, knee, ankle, and wrist.Insights into imaging · 2023Article
- Ultra-low-dose CT is feasible for torsion measurement of the lower limb in patients with metal implants.The British journal of radiology · 2023Article
- Feasibility study of three-dimensional printing knee model using the ultra-low-dose CT scan for preoperative planning and simulated surgery.Insights into imaging · 2022Article
- Ultra-low dose CT for scaphoid fracture detection-a simulational approach to quantify the capability of radiation exposure reduction without diagnostic limitation.Quantitative imaging in medicine and surgery · 2022Article
- Early results of ultra-low-dose CT-scan for extremity traumas in emergency room.Quantitative imaging in medicine and surgery · 2022Article
- Dose reduction potential in cone-beam CT imaging of upper extremity joints with a twin robotic x-ray system.Scientific reports · 2021Article
- Radiation Dose Reduction in CT Torsion Measurement of the Lower Limb: Introduction of a New Ultra-Low Dose Protocol.Diagnostics (Basel, Switzerland) · 2021Article
- Computer-assisted femoral head reduction osteotomies: an approach for anatomic reconstruction of severely deformed Legg-Calvé-Perthes hips. A pilot study of six patients.BMC musculoskeletal disorders · 2020Article
- A real 3D measurement technique for the tibial slope: differentiation between different articular surfaces and comparison to radiographic slope measurement.BMC musculoskeletal disorders · 2020Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
objectiveThe purpose of this study was to assess if ultra-low-dose CT is a useful clinical alternative to digital radiographs in the evaluation of acute wrist and ankle fractures. MATERIALS AND
methodsAn ultra-low-dose protocol was designed on a 256-slice multi-detector CT. Patients from the emergency department were evaluated prospectively. After initial digital radiographs, an ultra-low-dose CT was performed. Two readers independently analyzed the images. Also, the radiation dose, examination time, and time to preliminary report was compared between digital radiographs and CT.
resultsIn 207 extremities, digital radiography and ultra-low-dose CT detected 73 and 109 fractures, respectively (p < 0.001). The odds ratio for fracture detection with ultra-low-dose CT vs. digital radiography was 2.0 (95% CI, 1.4-3.0). CT detected additional fracture-related findings in 33 cases (15.9%) and confirmed or ruled out suspected fractures in 19 cases (9.2%). The mean effective dose was comparable between ultra-low-dose CT and digital radiography (0.59 ± 0.33 μSv, 95% CI 0.47-0.59 vs. 0.53 ± 0.43 μSv, 95% CI 0.54-0.64). The mean combined examination time plus time to preliminary report was shorter for ultra-low-dose CT compared to digital radiography (7.6 ± 2.5 min, 95% CI 7.1-8.1 vs. 9.8 ± 4.7 min, 95% CI 8.8-10.7) (p = 0.002). The recommended treatment changed in 34 (16.4%) extremities.
conclusionsUltra-low-dose CT is a useful alternative to digital radiography for imaging the peripheral skeleton in the acute setting as it detects significantly more fractures and provides additional clinically important information, at a comparable radiation dose. It also provides faster combined examination and reporting times.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials