ArticleSensors (Basel, Switzerland)2019
Self-Referenced Optical Fiber Sensor for Hydrogen Peroxide Detection based on LSPR of Metallic Nanoparticles in Layer-by-Layer Films.
Article in Sensors (Basel, Switzerland), 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
5 citing papers in PubMed, 21 citations in OpenAlex.
- Study of a Nanostructured Co-Doped SnOACS omega · 2025Article
- Recent Advancements of LSPR Fiber-Optic Biosensing: Combination Methods, Structure, and Prospects.Biosensors · 2023Review
- Room Temperature Detection of Hydrogen Peroxide Vapor by FeNanomaterials (Basel, Switzerland) · 2022Article
- A Long-Term Stable Sensor Based on Fe@PCN-224 for Rapid and Quantitative Detection of HFoods (Basel, Switzerland) · 2021Article
- HgSensors (Basel, Switzerland) · 2019Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors at 1 institution in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Intensity-based optical fiber sensors are one of the most studied sensor approaches thanks to their simplicity and low cost. Nevertheless, their main issue is their lack of robustness since any light source fluctuation, or unexpected optical setup variation is directly transferred to the output signal, which, significantly reduces their reliability. In this work, a simple and robust hydrogen peroxide (H
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.