Evidence map›Paper›PMID 31500195›Full record

ArticleSensors (Basel, Switzerland)2019

Active Body Pressure Relief System with Time-of-Flight Optical Pressure Sensors for Pressure Ulcer Prevention.

Kang-Ho Lee, Yeong-Eun Kwon, Hyukjin Lee, Yongkoo Lee, Joonho Seo, Ohwon Kwon, Shin-Won Kang, Dongkyu Lee

Open access · goldAbstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
8.7field-weighted citation impact, top 3% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed, 30 citations in OpenAlex.

  1. Article
  2. Article
  3. [Modeling and comfort analysis of arrayed air cushion mattress for pressure ulcer prevention and assisted repositioning].Sheng wu yi xue gong cheng xue za zhi = Journal of biomedical engineering = Shengwu yixue gongchengxue zazhi · 2024
    Article
  4. Article
  5. Article
  6. Smart Sensors for Healthcare and Medical Applications.Sensors (Basel, Switzerland) · 2021
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 2 institutions in 1 country.

Kang-Ho LeeDaegu Research Center for Medical Devices, Korea institute of Machinery and Materials, Daegu 42994, Korea.
Yeong-Eun KwonDaegu Research Center for Medical Devices, Korea institute of Machinery and Materials, Daegu 42994, Korea.
Hyukjin LeeDaegu Research Center for Medical Devices, Korea institute of Machinery and Materials, Daegu 42994, Korea.
Yongkoo LeeDaegu Research Center for Medical Devices, Korea institute of Machinery and Materials, Daegu 42994, Korea.
Joonho SeoDaegu Research Center for Medical Devices, Korea institute of Machinery and Materials, Daegu 42994, Korea.
Ohwon KwonDaegu Research Center for Medical Devices, Korea institute of Machinery and Materials, Daegu 42994, Korea.ORCID 0000-0001-9830-9943
Shin-Won KangSchool of Electronics Engineering, College of IT Engineering, Kyungpook National University, Daegu 41566, Korea. swkang@knu.ac.kr.
Dongkyu LeeDaegu Research Center for Medical Devices, Korea institute of Machinery and Materials, Daegu 42994, Korea. dongkyu@kimm.re.kr.
Korea Institute of Machinery & Materials · KRKyungpook National University · KR

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

A body pressure relief system was newly developed with optical pressure sensors for pressure ulcer prevention. Unlike a conventional alternating pressure air mattress (APAM), this system automatically regulates air flow into a body supporting mattress with adaptive inflation (or deflation) duration in response to the pressure level in order to reduce skin stress due to prolonged high pressures. The system continuously quantifies the body pressure distribution using time-of-flight (ToF) optical sensors. The proposed pressure sensor, a ToF optical sensor in the air-filled cell, measures changes in surface height of mattress when pressed under body weight, thereby indirectly indicating the interface pressure. Non-contact measurement of optical sensor usually improves the durability and repeatability of the system. The pressure sensor was successfully identified the 4 different-predefined postures, and quantitatively measured the body pressure distribution of them. Duty cycle of switches in solenoid valves was adjusted to 0-50% for pressure relief, which shows that the interface pressure was lower than 32 mmHg for pressure ulcer prevention.

Indexed as

active control systemair-filled cellair flowalternating pressure air mattressbody pressure distributiontime of flight

Identifiers

PMID31500195
PMCPMC6766802
OpenAlexW2971374616

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.