ArticleMedical physics2019
Effect of source blur on digital breast tomosynthesis reconstruction.
Article in Medical physics, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 9 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
9 citing papers in PubMed.
- Focal spot motion in digital breast tomosynthesis and its effect on spatial resolution.Journal of applied clinical medical physics · 2026Article
- Hybrid simulation of breast CT for assessing microcalcification detectability.Journal of medical imaging (Bellingham, Wash.) · 2025Article
- Evaluation of the flying focal spot technology in a wide-angle digital breast tomosynthesis system.Journal of medical imaging (Bellingham, Wash.) · 2025Article
- Article
- X-ray source motion blur modeling and deblurring with generative diffusion for digital breast tomosynthesis.Physics in medicine and biology · 2024Article
- Model-based deep CNN-regularized reconstruction for digital breast tomosynthesis with a task-based CNN image assessment approach.Physics in medicine and biology · 2023Article
- Tomographic detection of photon pairs produced from high-energy X-rays for the monitoring of radiotherapy dosing.Nature biomedical engineering · 2023Article
- Variation in digital breast tomosynthesis image quality at differing heights above the detector.Journal of medical radiation sciences · 2022Article
- Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
3 authors.
Funding
Abstract
purposeMost digital breast tomosynthesis (DBT) reconstruction methods neglect the blurring of the projection views caused by the finite size or motion of the x-ray focal spot. This paper studies the effect of source blur on the spatial resolution of reconstructed DBT using analytical calculation and simulation, and compares the influence of source blur over a range of blurred source sizes.
methodsMathematically derived formulas describe the point spread function (PSF) of source blur on the detector plane as a function of the spatial locations of the finite-sized source and the object. By using the available technical parameters of some clinical DBT systems, we estimated the effective source sizes over a range of exposure time and DBT scan geometries. We used the CatSim simulation tool (GE Global Research, NY) to generate digital phantoms containing line pairs and beads at different locations and imaged with sources of four different sizes covering the range of potential source blur. By analyzing the relative contrasts of the test objects in the reconstructed images, we studied the effect of the source blur on the spatial resolution of DBT. Furthermore, we simulated a detector that rotated in synchrony with the source about the rotation center and calculated the spatial distribution of the blurring distance in the imaged volume to estimate its influence on source blur.
resultsCalculations demonstrate that the PSF is highly shift-variant, making it challenging to accurately implement during reconstruction. The results of the simulated phantoms demonstrated that a typical finite-sized focal spot (~0.3 mm) will not affect the reconstructed image resolution if the x-ray tube is stationary during data acquisition. If the x-ray tube moves during exposure, the extra blur due to the source motion may degrade image resolution, depending on the effective size of the source along the direction of the motion. A detector that rotates in synchrony with the source does not reduce the influence of source blur substantially.
conclusionsThis study demonstrates that the extra source blur due to the motion of the x-ray tube during image acquisition substantially degrades the reconstructed image resolution. This effect cannot be alleviated by rotating the detector in synchrony with the source. The simulation results suggest that there are potential benefits of modeling the source blur in image reconstruction for DBT systems using continuous-motion acquisition mode.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials