Evidence map›Paper›PMID 31490142›Full record

ArticleJournal of synchrotron radiation2019

Device for source position stabilization and beam parameter monitoring at inverse Compton X-ray sources.

Benedikt Günther, Martin Dierolf, Klaus Achterhold, Franz Pfeiffer

Open access · hybridAbstract read
In one paragraph

Article in Journal of synchrotron radiation, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
2.4field-weighted citation impact, top 12% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 13 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 1 institution in 1 country.

Benedikt GüntherDepartment of Physics, Technical University of Munich, James-Franck-Straße 1, 85748 Garching, Germany.
Martin DierolfDepartment of Physics, Technical University of Munich, James-Franck-Straße 1, 85748 Garching, Germany.
Klaus AchterholdDepartment of Physics, Technical University of Munich, James-Franck-Straße 1, 85748 Garching, Germany.
Franz PfeifferDepartment of Physics, Technical University of Munich, James-Franck-Straße 1, 85748 Garching, Germany.
Technical University of Munich · DE

Funding

Deutsche Forschungsgemeinschaft Gottfried Wilhelm Leibniz-PreisDeutsche Forschungsgemeinschaft Munich-Centre for Advanced Photonics DFG EXC-158
6 · The paper itself

Abstract

Compact X-ray sources based on inverse Compton scattering provide brilliant and partially coherent X-rays in a laboratory environment. The cross section for inverse Compton scattering is very small, requiring high-power laser systems as well as small laser and electron beam sizes at the interaction point to generate sufficient flux. Therefore, these systems are very sensitive to distortions which change the overlap between the two beams. In order to monitor X-ray source position, size and flux in parallel to experiments, the beam-position monitor proposed here comprises a small knife edge whose image is acquired with an X-ray camera specifically designed to intercept only a very small fraction of the X-ray beam. Based on the source position drift recorded with the monitor, a closed-loop feedback stabilizes the X-ray source position by adjusting the laser beam trajectory. A decrease of long-term source position drifts by more than one order of magnitude is demonstrated with this device. Consequently, such a closed-loop feedback system which enables stabilization of source position drifts and flux of inverse Compton sources in parallel to experiments has a significant impact on the performance of these sources.

Indexed as

active source position stabilizationbeam-position monitorinverse Compton X-ray sources

Identifiers

PMID31490142
PMCPMC6730616
OpenAlexW2965750444

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.