ArticleDocumenta ophthalmologica. Advances in ophthalmology2020

Use of diffusing filters for artificially reducing visual acuity when testing equipment and procedures.

Sven P Heinrich, Isabell Strübin

Abstract read
PubMed Publisher
In one paragraph

Article in Documenta ophthalmologica. Advances in ophthalmology, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 9 papers.

0numbers the graph read from it
0cells of the map it votes in
9citing papers in PubMed
0.6field-weighted citation impact, top 33% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

9 citing papers in PubMed, 14 citations in OpenAlex.

  1. Article
  2. Article
  3. Dioptric blur is not fully reflected by VEP-based visual acuity estimates.Documenta ophthalmologica. Advances in ophthalmology · 2025
    Article
  4. The FreiBurger: a new optotype for P300-based acuity estimation.Documenta ophthalmologica. Advances in ophthalmology · 2024
    Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. VEP-based acuity estimation: unaffected by translucency of contralateral occlusion.Documenta ophthalmologica. Advances in ophthalmology · 2021
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

2 authors at 1 institution in 1 country.

Sven P HeinrichEye Center, Medical Center, University of Freiburg, Killianstr. 5, 79106, Freiburg, Germany. sven.heinrich@uni-freiburg.de.ORCID 0000-0003-4906-3937
Isabell StrübinEye Center, Medical Center, University of Freiburg, Killianstr. 5, 79106, Freiburg, Germany.
University of Freiburg · DE

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeWhen evaluating ophthalmological devices and procedures, for instance those for visual electrophysiology, it is often desirable to perform tests with reduced acuity. Doing this with individuals with actual visual impairments has a number of disadvantages, such as considerable recruitment efforts, especially when a specific acuity range is targeted, and little control about the actual perceptual characteristics of the impairment, which are normally not fully known. Lenses with positive diopters or blurring filters that are placed in front of the eyes of visually normal observers promise a simple solution to the problem. However, defocus results in considerable spurious resolution, and previous studies suggest that the frequently used Bangerter occluders are not optimal for the purpose. The present study therefore reviews a number of other options and tests a selection of filters with respect to their effect on acuity and contrast sensitivity with the aim of identifying filters that primarily degrade acuity while mostly sparing contrast sensitivity.

methodsFirst, we screened several filters for potential usefulness. The Freiburg Acuity and Contrast Test was then used to measure visual acuity and contrast sensitivity with a subset of three filters (Luminit LSD 0.5° and 1°, and LEE 420) and, for comparison, with a Bangerter occluder with a nominal acuity grade of 0.1. A qualitative comparison of the filters' effect on the checkerboard-reversal VEP was also performed.

resultsWith both Luminit filters, variability in acuity across participants was relatively small, and at least with the 0.5° version, contrast sensitivity was relativity little affected. The LEE filter and the Bangerter occluder resulted in more variability and, compared to the effect on acuity, a relatively strong reduction in contrast sensitivity. Comparing the Luminit 0.5° and 1° filters, the reduction of acuity was not proportional to physical stimulus degradation. The effect on VEP responses was consistent with the psychophysical data.

conclusionsThe Luminit filters, which have a Gaussian light diffusion profile, appear to be a good choice for artificial reduction of acuity.

Indexed as

AdultContrast SensitivityElectroretinographyFemaleFiltrationHumansMaleVisual AcuityArtificial degradationBlurContrast sensitivityObserver methodOcclusionVisual acuity