ArticleEuropean radiology2020
CT and MR imaging prior to transcatheter aortic valve implantation: standardisation of scanning protocols, measurements and reporting-a consensus document by the European Society of Cardiovascular Radiology (ESCR).
Article in European radiology, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. An erratum has been issued. Cited by 114 papers, 4 of them syntheses that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
114 citing papers in PubMed, 4 syntheses or guidelines pooled it.
- Preoperative visit-care for transcatheter aortic valve replacement: a review.BMC cardiovascular disorders · 2024Pooled it
- Renal outcomes in valve-in-valve transcatheter versus redo surgical aortic valve replacement: A systematic review and meta-analysis.Journal of cardiac surgery · 2022Pooled it
- Pooled it
- The current landscape of imaging recommendations in cardiovascular clinical guidelines: toward an imaging-guided precision medicine.La Radiologia medica · 2020Pooled it
- Video-assisted informed consent in cardiac imaging: influence on patient experience during CT-the randomized controlled VAICICI Trial.European radiology · 2026Trial
- Transaortic TAVR and MICS-CABG in a Patient on Dialysis With RCA Restenosis.JACC. Case reports · 2026Article
- Same-Day Discharge After Transcatheter Aortic Valve Implantation: Who, When, and How?Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions · 2026Review
- Echo Chambers: Bias and Representation in Cardiac Imaging Datasets for Artificial Intelligence.Current cardiology reports · 2026Review
- Influence of The Cusp-Overlap and three cusps coplanar techniques on new-onset conduction disturbances following transcatheter aortic valve implantation.Cardiovascular intervention and therapeutics · 2026Article
- Deep Learning-Derived Body Composition Analysis Predicts Long-Term Mortality After Transcatheter Aortic Valve Replacement.Mayo Clinic proceedings. Digital health · 2026Article
- Highlights from the first interdisciplinary summit of the European Association of Cardiovascular Imaging and the European Society for Cardiovascular Radiology.European heart journal. Cardiovascular Imaging · 2026Article
- Highlights from the first interdisciplinary summit of the European Association of Cardiovascular Imaging and the European Society for Cardiovascular Radiology.Insights into imaging · 2026Article
- Diagnostic Performance of Photon-Counting CT Angiography in Vascular Stenosis Assessment: A Systematic Review and Meta-Analysis.Diagnostics (Basel, Switzerland) · 2026Review
- Evolving capabilities of computed tomography imaging for transcatheter valvular heart interventions - new opportunities for precision medicine.The international journal of cardiovascular imaging · 2026Review
- Role of Cardiac CT in the Evaluation of Valvular Heart Disease.Journal of the Korean Society of Radiology · 2026Review
- Indexed Aortic Valve Calcium Volume by Computed Tomography Angiography in Patients With Aortic Stenosis: Results of an International Multicenter Cohort Study.JACC. Cardiovascular imaging · 2026Observational
- Multi-chamber three-dimensional myocardial strain assessment by computed tomography: a comparison with speckle tracking echocardiography and association with pulmonary hypertension in severe aortic stenosis.Frontiers in cardiovascular medicine · 2026Article
- Multidetector Computed Tomography and Aortic Stenosis: The Emerging Potential of Bridging Morphology and Severity Grading.Diagnostics (Basel, Switzerland) · 2025Article
- Diagnostic Accuracy of Coronary CT Angiography in Ruling Out Significant Coronary Artery Disease in Candidates for Transcatheter Aortic Valve Replacement.Journal of cardiovascular development and disease · 2025Article
- Prognostic Value of Pericoronary Adipose Tissue Attenuation After Transcatheter Aortic Valve Replacement in Patients With Aortic Stenosis and Obstructive Coronary Artery Disease.Reviews in cardiovascular medicine · 2025Article
54 more citing papers are in PubMed but not listed here.
Corrections and comments
- Erratum issued
Authors and funding
13 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Transcatheter aortic valve replacement (TAVR) is a minimally invasive alternative to conventional aortic valve replacement in symptomatic patients with severe aortic stenosis and contraindications to surgery. The procedure has shown to improve patient's quality of life and prolong short- and mid-term survival in high-risk individuals, becoming a widely accepted therapeutic option which has been integrated into current clinical guidelines for the management of valvular heart disease. Nevertheless, not every patient at high-risk for surgery is a good candidate for TAVR. Besides clinical selection, which is usually established by the Heart Team, certain technical and anatomic criteria must be met as, unlike in surgical valve replacement, annular sizing is not performed under direct surgical evaluation but on the basis of non-invasive imaging findings. Present consensus document was outlined by a working group of researchers from the European Society of Cardiovascular Radiology (ESCR) and aims to provide guidance on the utilisation of CT and MR imaging prior to TAVR. Particular relevance is given to the technical requirements and standardisation of the scanning protocols which have to be tailored to the remarkable variability of the scanners currently utilised in clinical practice; recommendations regarding all required pre-procedural measurements and medical reporting standardisation have been also outlined, in order to ensure quality and consistency of reported data and terminology. KEY POINTS: • To provide a reference document for CT and MR acquisition techniques, taking into account the significant technological variation of available scanners. • To review all relevant measurements that are required and define a step-by-step guided approach for the measurements of different structures implicated in the procedure. • To propose a CT/MR reporting template to assist in consistent communication between various sites and specialists involved in the procedural planning.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials