Performance of Dynamic Automated CT Annular Measurements Compared to Standard Manual Measurements for Transcatheter Aortic Valve Replacement Sizing.

Quynh A Truong, Alan C Legasto, Roderick C Deaño, Daniel P Bachman, Deep Bhatt, Subhi J Al'Aref, Richard B Devereux, S Chiu Wong, Arash Salemi, Jackie Szymonifka

Abstract read
In one paragraph

Article in Radiology. Cardiothoracic imaging, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors.

Quynh A TruongDepartment of Radiology, Weill Cornell Medicine, New York, NY.
Alan C LegastoDepartment of Radiology, Weill Cornell Medicine, New York, NY.
Roderick C DeañoDivision of Cardiology, Department of Medicine, University of Wisconsin, Madison, WI.
Daniel P BachmanDivision of Cardiology, Department of Medicine, Weill Cornell Medicine, New York, NY.
Deep BhattDepartment of Medicine, Weill Cornell Medicine, New York, NY.
Subhi J Al'ArefDepartment of Radiology, Weill Cornell Medicine, New York, NY.
Richard B DevereuxDivision of Cardiology, Department of Medicine, Weill Cornell Medicine, New York, NY.
S Chiu WongDivision of Cardiology, Department of Medicine, Weill Cornell Medicine, New York, NY.
Arash SalemiDepartment of Cardiothoracic Surgery, Weill Cornell Medicine, New York, NY.
Jackie SzymonifkaDepartment of Biostatistics, New York University, New York, NY.

Funding

Computed Tomography to Predict Response to Cardiac Resynchronization TherapyK23HL098370 · NHLBI · WEILL MEDICAL COLL OF CORNELL UNIV · PI TRUONG, QUYNH A. · 2010 to 2014
$816k
NHLBI NIH HHS K23 HL098370
6 · The paper itself

Abstract

purposeWe sought to determine the performance of an automated computed tomography (CT) software that provides dynamic annular measurements of all available cardiac phases for transcatheter aortic valve replacement (TAVR) sizing as compared to the standard single manual measurement. MATERIALS AND

methodsIn 60 TAVR patients (84±7 years, 60% male) who underwent pre-procedural CT scans, we measured the aortic annular diameters, perimeter, and area using (1) the dynamic automated CT measurements and (2) standard single manual measurement from the cardiac phase of maximum systolic opening by visual estimate.

resultsThe automated software was successful in providing annular measurements in 43/60 (72%) of cases, with the remainder requiring semi-automated contours. The maximum dynamic automated values were predominantly in systole (46/60[77%] for diameter, 44/60[73%] for perimeter, 48/60[80%] for area), and was a different phase from the standard manual phase in 46/60 (77%) cases. The maximum dynamic automated annular values were larger than the standard manual values measured (Δdiameter 0.35 mm, p=0.04; Δperimeter 1.71 mm, p<0.001; Δarea 15.6 mm

conclusionsAutomated maximum dynamic CT annular measurements provide larger values than standard manual and same phase automated measurements.

Indexed as

[150] Imaging[30] CT and MRIaortic stenosiscomputed tomographytranscatheter aortic valve replacement

Identifiers

PMID31489405
PMCPMC6727651

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.