ArticleACS sensors2019
Noninvasively Imaging pH at the Surface of Implanted Orthopedic Devices with X-ray Excited Luminescence Chemical Imaging.
Article in ACS sensors, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 12 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
12 citing papers in PubMed.
- [Computer-assisted sensing in periprosthetic joint infection : Current evidence and future perspectives for wearables].Orthopadie (Heidelberg, Germany) · 2026Review
- Toward Noninvasively Imaging pH at the Surface of Implanted Orthopedic Devices in Live Rabbits Using X-ray Excited Luminescence Chemical Imaging.Advanced healthcare materials · 2025Article
- Imaging Oxygen Concentrations in Bone Scaffolds during Cellular Activity and Fluid Perfusion.ACS biomaterials science & engineering · 2025Article
- Local protein detection with lateral flow assay read through tissue using X-ray excited luminescence chemical imaging.Journal of biomedical optics · 2025Article
- The rational design, biofunctionalization and biological properties of orthopedic porous titanium implants: a review.Frontiers in bioengineering and biotechnology · 2025Review
- Spatial Resolution for X-ray Excited Luminescence Chemical Imaging (XELCI).Chemical & biomedical imaging · 2024Article
- Finite element-based feasibility study on utilizing heat flux sensors for early detection of vascular graft infections.Scientific reports · 2023Article
- Advanced surface engineering of titanium materials for biomedical applications: From static modification to dynamic responsive regulation.Bioactive materials · 2023Review
- Surface-Doped Zinc Gallate Colloidal Nanoparticles Exhibit pH-Dependent Radioluminescence with Enhancement in Acidic Media.Nano letters · 2023Article
- pH variation in medical implant biofilms: Causes, measurements, and its implications for antibiotic resistance.Frontiers in microbiology · 2022Review
- Synovial fluid pH sensor for early detection of prosthetic hip infections.Advanced functional materials · 2021Article
- Review of in vivo optical molecular imaging and sensing from x-ray excitation.Journal of biomedical optics · 2021Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors.
Funding
Abstract
Implanted medical device-associated infections are a leading cause of fixation failure, and early diagnosis is the key to successful treatment. During infection, acidosis near the implant plays a role in antibiotic resistance and low pH is a potential infection indicator. Herein, we describe a pH sensor which attaches to the implants to noninvasively image local pH with high spatial resolution. The sensor has two layers: a scintillator layer which emits 620 and 700 nm light upon X-ray irradiation and a pH indicator layer containing bromocresol green dye that absorbs 620 nm luminescence in neutral/basic pH and passes 700 nm light at all pHs. We also developed a dedicated imaging system capable of scanning relatively large specimens through thick tissues. A focused X-ray beam irradiates one spot on the sensor, and the 620 to 700 nm peak ratio is measured to determine the local pH; images are acquired by scanning the X-ray beam across the surface and measuring the pH point-by-point. The sensor was covered with varying thickness slices of chicken breast tissue (0-19 mm) to evaluate how the tissue affects the peak intensity and ratio. Thick tissues attenuated both 620 and 700 nm light, with more attenuation at 620 nm than 700 nm. Although this spectral distortion shifted the pH calibration curve, the effect could be corrected for using a scintillator film region with no pH indicator layer as a spectral reference. The sensor was attached to an orthopedic plate affixed to a human cadaveric tibia and imaged through tissue. This approach provides both high spatial resolution from focused X-ray excitation and surface chemical specificity from the indicator dye, providing a tool for imaging local pH through tissue.